Abstract
The paper is devoted to determination of neutron detector efficiency in 0.1-500 MeV energy range with the error of 10% maximum using complex investigation method. Detectors of the Neutron Spectrometer facility based on LVEh-OIYaI synchrotron, were investigated, namely, the detector based on stilbene crystal with dimensions of 40x10 mm for low energy range, the detector based on 50x50 mm stilbene for 2-500 MeV energy range and the detector based on 120x200 mm plastic scintillator (polystyrene with p-terphenyl and POPOP additions) for energies above 20 MeV. 21 refs.; 6 figs.; 2 tabs.
Citation Formats
Lyapin, V G, Tsvetkov, I O, Yurevich, V I, and Yakovlev, R M.
Investigation of efficiency of neutron detection by detectors based on organic scintillators; Issledovanie ehffektivnosti registratsii nejtronov detektorami na osnove organicheskikh stsintillyatorov.
USSR: N. p.,
1990.
Web.
Lyapin, V G, Tsvetkov, I O, Yurevich, V I, & Yakovlev, R M.
Investigation of efficiency of neutron detection by detectors based on organic scintillators; Issledovanie ehffektivnosti registratsii nejtronov detektorami na osnove organicheskikh stsintillyatorov.
USSR.
Lyapin, V G, Tsvetkov, I O, Yurevich, V I, and Yakovlev, R M.
1990.
"Investigation of efficiency of neutron detection by detectors based on organic scintillators; Issledovanie ehffektivnosti registratsii nejtronov detektorami na osnove organicheskikh stsintillyatorov."
USSR.
@misc{etde_10128327,
title = {Investigation of efficiency of neutron detection by detectors based on organic scintillators; Issledovanie ehffektivnosti registratsii nejtronov detektorami na osnove organicheskikh stsintillyatorov}
author = {Lyapin, V G, Tsvetkov, I O, Yurevich, V I, and Yakovlev, R M}
abstractNote = {The paper is devoted to determination of neutron detector efficiency in 0.1-500 MeV energy range with the error of 10% maximum using complex investigation method. Detectors of the Neutron Spectrometer facility based on LVEh-OIYaI synchrotron, were investigated, namely, the detector based on stilbene crystal with dimensions of 40x10 mm for low energy range, the detector based on 50x50 mm stilbene for 2-500 MeV energy range and the detector based on 120x200 mm plastic scintillator (polystyrene with p-terphenyl and POPOP additions) for energies above 20 MeV. 21 refs.; 6 figs.; 2 tabs.}
place = {USSR}
year = {1990}
month = {Dec}
}
title = {Investigation of efficiency of neutron detection by detectors based on organic scintillators; Issledovanie ehffektivnosti registratsii nejtronov detektorami na osnove organicheskikh stsintillyatorov}
author = {Lyapin, V G, Tsvetkov, I O, Yurevich, V I, and Yakovlev, R M}
abstractNote = {The paper is devoted to determination of neutron detector efficiency in 0.1-500 MeV energy range with the error of 10% maximum using complex investigation method. Detectors of the Neutron Spectrometer facility based on LVEh-OIYaI synchrotron, were investigated, namely, the detector based on stilbene crystal with dimensions of 40x10 mm for low energy range, the detector based on 50x50 mm stilbene for 2-500 MeV energy range and the detector based on 120x200 mm plastic scintillator (polystyrene with p-terphenyl and POPOP additions) for energies above 20 MeV. 21 refs.; 6 figs.; 2 tabs.}
place = {USSR}
year = {1990}
month = {Dec}
}