Abstract
Conception of this equipment was born of the necessity for a system suitalbe for optimizing the methods employed up to the present in ININ, for calibrating portalbe gamma radiation monitors for radiological protection of the need for a national level reference laboratory. The equipment parts are: a multisource irradiator, a system for the transport and positioning of radiation monitors, an aerial conveyor ANS a control panel. The multisource irradiator, which is shielded container, houses five Cs-137 and Co-60 different activity radiative sources. The transport and positioning radiation monitor system places the monitors for calibration at the required distance and height. The instrument source distance can be selected from the control panel. The instrument source distance and detector readings can be verified by means of a closed TV circuit. The activity of the radiation sources, using varying combinations of instrument source distances, has been characterized for each of the radiative sources and all the calibration parameters of the radiation beam central axis are known to a precision of within 3.0 % error. (Author).
Citation Formats
Mariano-Heredia, E.
Fabrication and mount of a multisource irradiation systems; Fabricacion y montaje de un sistema de irradiacion multifuente.
Mexico: N. p.,
1990.
Web.
Mariano-Heredia, E.
Fabrication and mount of a multisource irradiation systems; Fabricacion y montaje de un sistema de irradiacion multifuente.
Mexico.
Mariano-Heredia, E.
1990.
"Fabrication and mount of a multisource irradiation systems; Fabricacion y montaje de un sistema de irradiacion multifuente."
Mexico.
@misc{etde_10127977,
title = {Fabrication and mount of a multisource irradiation systems; Fabricacion y montaje de un sistema de irradiacion multifuente}
author = {Mariano-Heredia, E}
abstractNote = {Conception of this equipment was born of the necessity for a system suitalbe for optimizing the methods employed up to the present in ININ, for calibrating portalbe gamma radiation monitors for radiological protection of the need for a national level reference laboratory. The equipment parts are: a multisource irradiator, a system for the transport and positioning of radiation monitors, an aerial conveyor ANS a control panel. The multisource irradiator, which is shielded container, houses five Cs-137 and Co-60 different activity radiative sources. The transport and positioning radiation monitor system places the monitors for calibration at the required distance and height. The instrument source distance can be selected from the control panel. The instrument source distance and detector readings can be verified by means of a closed TV circuit. The activity of the radiation sources, using varying combinations of instrument source distances, has been characterized for each of the radiative sources and all the calibration parameters of the radiation beam central axis are known to a precision of within 3.0 % error. (Author).}
place = {Mexico}
year = {1990}
month = {Dec}
}
title = {Fabrication and mount of a multisource irradiation systems; Fabricacion y montaje de un sistema de irradiacion multifuente}
author = {Mariano-Heredia, E}
abstractNote = {Conception of this equipment was born of the necessity for a system suitalbe for optimizing the methods employed up to the present in ININ, for calibrating portalbe gamma radiation monitors for radiological protection of the need for a national level reference laboratory. The equipment parts are: a multisource irradiator, a system for the transport and positioning of radiation monitors, an aerial conveyor ANS a control panel. The multisource irradiator, which is shielded container, houses five Cs-137 and Co-60 different activity radiative sources. The transport and positioning radiation monitor system places the monitors for calibration at the required distance and height. The instrument source distance can be selected from the control panel. The instrument source distance and detector readings can be verified by means of a closed TV circuit. The activity of the radiation sources, using varying combinations of instrument source distances, has been characterized for each of the radiative sources and all the calibration parameters of the radiation beam central axis are known to a precision of within 3.0 % error. (Author).}
place = {Mexico}
year = {1990}
month = {Dec}
}