The maximum coefficient of performance of thermoelectric heat pumps

Abstract

The effect of three main irreversibilities existing in thermoelectric devices on the performance of a thermoelectric heat pump is investigated. The coefficient of performance and the heating load of the heat pump are derived. The optimal performance of the heat pump at maximum coefficient of performance is discussed, and the rational working region of the heat pump is determined. The optimal structure of the device is also described. The results obtained here are more realistic than those derived from non-equilibrium thermodynamics. (au) (12 refs.)
Publication Date:
Dec 31, 1994
Product Type:
Technical Report
Report Number:
KU-HCOE-NBI-R-1994-09
Reference Number:
SCA: 320303; PA: DK-95:001265; EDB-95:051551; SN: 95001360189
Resource Relation:
Other Information: PBD: 1994
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; HEAT PUMPS; THERMOELECTRIC HEATERS; COEFFICIENT OF PERFORMANCE; IRREVERSIBLE PROCESSES; SEMICONDUCTOR MATERIALS; HEAT TRANSFER; 320303; EQUIPMENT AND PROCESSES
OSTI ID:
10127902
Research Organizations:
Niels Bohr Inst. for Astronomi, Fysik og Geofysik, Copenhagen (Denmark). Oersted Lab.
Country of Origin:
Denmark
Language:
English
Other Identifying Numbers:
Other: ON: DE95755108; CNN: Contract CIPA-CT92-4206; TRN: DK9501265
Availability:
OSTI; NTIS
Submitting Site:
DK
Size:
21 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Chen, Jincan, and Andresen, B. The maximum coefficient of performance of thermoelectric heat pumps. Denmark: N. p., 1994. Web.
Chen, Jincan, & Andresen, B. The maximum coefficient of performance of thermoelectric heat pumps. Denmark.
Chen, Jincan, and Andresen, B. 1994. "The maximum coefficient of performance of thermoelectric heat pumps." Denmark.
@misc{etde_10127902,
title = {The maximum coefficient of performance of thermoelectric heat pumps}
author = {Chen, Jincan, and Andresen, B}
abstractNote = {The effect of three main irreversibilities existing in thermoelectric devices on the performance of a thermoelectric heat pump is investigated. The coefficient of performance and the heating load of the heat pump are derived. The optimal performance of the heat pump at maximum coefficient of performance is discussed, and the rational working region of the heat pump is determined. The optimal structure of the device is also described. The results obtained here are more realistic than those derived from non-equilibrium thermodynamics. (au) (12 refs.)}
place = {Denmark}
year = {1994}
month = {Dec}
}