Abstract
Results of the tests carried out on one of the six Tore Supra neutral beam injectors are reported. Several minor modifications of the injector design allowed us to operate up to 92 keV - 30 A beams limited by the high voltage power supplies. Results of studies on different topics like new titanium pumping system, neutron yield from neutraliser and target, beam conditioning and breakdown statistical analysis are also reported.
Citation Formats
Fumelli, M, and Jequier, F.
Experimental results of Tore Supra neutral beam injector in the line testing system; Resultats de l`experimentation d`un injecteur de neutres Tore Supra dans le bati d`essai des lignes.
France: N. p.,
1991.
Web.
Fumelli, M, & Jequier, F.
Experimental results of Tore Supra neutral beam injector in the line testing system; Resultats de l`experimentation d`un injecteur de neutres Tore Supra dans le bati d`essai des lignes.
France.
Fumelli, M, and Jequier, F.
1991.
"Experimental results of Tore Supra neutral beam injector in the line testing system; Resultats de l`experimentation d`un injecteur de neutres Tore Supra dans le bati d`essai des lignes."
France.
@misc{etde_10126784,
title = {Experimental results of Tore Supra neutral beam injector in the line testing system; Resultats de l`experimentation d`un injecteur de neutres Tore Supra dans le bati d`essai des lignes}
author = {Fumelli, M, and Jequier, F}
abstractNote = {Results of the tests carried out on one of the six Tore Supra neutral beam injectors are reported. Several minor modifications of the injector design allowed us to operate up to 92 keV - 30 A beams limited by the high voltage power supplies. Results of studies on different topics like new titanium pumping system, neutron yield from neutraliser and target, beam conditioning and breakdown statistical analysis are also reported.}
place = {France}
year = {1991}
month = {Apr}
}
title = {Experimental results of Tore Supra neutral beam injector in the line testing system; Resultats de l`experimentation d`un injecteur de neutres Tore Supra dans le bati d`essai des lignes}
author = {Fumelli, M, and Jequier, F}
abstractNote = {Results of the tests carried out on one of the six Tore Supra neutral beam injectors are reported. Several minor modifications of the injector design allowed us to operate up to 92 keV - 30 A beams limited by the high voltage power supplies. Results of studies on different topics like new titanium pumping system, neutron yield from neutraliser and target, beam conditioning and breakdown statistical analysis are also reported.}
place = {France}
year = {1991}
month = {Apr}
}