Abstract
On the basis of the analysis of the experimental data from MASPIC spectrometer the performances of different scintillators used in the time-of-flight measurements have been investigated. The time resolutions of the tested counter pairs were between 550 and 680 ps (FWHM). Correlation between the time resolution of the time-of-flight system and the effective attenuation length of the long scintillators is observed. The measurements of an effective propagation velocity of light in the tested scintillators have shown that its magnitude depends on scintillator features. 15 refs.; 6 figs.; 2 tabs.
Citation Formats
Azhgirej, L S, Vzorov, I K, Ignatenko, M A, and Stoletov, G D.
Some performances of the time-of-flight scintillation counters based on polystyrene, paraterfenil and POPOP; Nekotorye kharakteristiki vremyaproletnykh stsintillyatsionnykh schetchikov na osnove stsintillyatora iz polistirola, paraterfenila i POPOP.
JINR: N. p.,
1991.
Web.
Azhgirej, L S, Vzorov, I K, Ignatenko, M A, & Stoletov, G D.
Some performances of the time-of-flight scintillation counters based on polystyrene, paraterfenil and POPOP; Nekotorye kharakteristiki vremyaproletnykh stsintillyatsionnykh schetchikov na osnove stsintillyatora iz polistirola, paraterfenila i POPOP.
JINR.
Azhgirej, L S, Vzorov, I K, Ignatenko, M A, and Stoletov, G D.
1991.
"Some performances of the time-of-flight scintillation counters based on polystyrene, paraterfenil and POPOP; Nekotorye kharakteristiki vremyaproletnykh stsintillyatsionnykh schetchikov na osnove stsintillyatora iz polistirola, paraterfenila i POPOP."
JINR.
@misc{etde_10126093,
title = {Some performances of the time-of-flight scintillation counters based on polystyrene, paraterfenil and POPOP; Nekotorye kharakteristiki vremyaproletnykh stsintillyatsionnykh schetchikov na osnove stsintillyatora iz polistirola, paraterfenila i POPOP}
author = {Azhgirej, L S, Vzorov, I K, Ignatenko, M A, and Stoletov, G D}
abstractNote = {On the basis of the analysis of the experimental data from MASPIC spectrometer the performances of different scintillators used in the time-of-flight measurements have been investigated. The time resolutions of the tested counter pairs were between 550 and 680 ps (FWHM). Correlation between the time resolution of the time-of-flight system and the effective attenuation length of the long scintillators is observed. The measurements of an effective propagation velocity of light in the tested scintillators have shown that its magnitude depends on scintillator features. 15 refs.; 6 figs.; 2 tabs.}
place = {JINR}
year = {1991}
month = {Dec}
}
title = {Some performances of the time-of-flight scintillation counters based on polystyrene, paraterfenil and POPOP; Nekotorye kharakteristiki vremyaproletnykh stsintillyatsionnykh schetchikov na osnove stsintillyatora iz polistirola, paraterfenila i POPOP}
author = {Azhgirej, L S, Vzorov, I K, Ignatenko, M A, and Stoletov, G D}
abstractNote = {On the basis of the analysis of the experimental data from MASPIC spectrometer the performances of different scintillators used in the time-of-flight measurements have been investigated. The time resolutions of the tested counter pairs were between 550 and 680 ps (FWHM). Correlation between the time resolution of the time-of-flight system and the effective attenuation length of the long scintillators is observed. The measurements of an effective propagation velocity of light in the tested scintillators have shown that its magnitude depends on scintillator features. 15 refs.; 6 figs.; 2 tabs.}
place = {JINR}
year = {1991}
month = {Dec}
}