Abstract
Sensitivity change has been studied of different types of CR-39 detectors (Pershore, Tastrak, Intercast, Ma-ND/{alpha}) in dependence on holding time of detector in vacuum chamber at the residual pressure P {approx_equal} 2x10{sup -2} and {approx_equal} 5x10{sup -3} Pa before their irradiation with alpha particles from thin {sup 238}Pu source and accelerated charged ions with atomic number Z=2-10 and energy of 9.1 MeV/nucleon. Polymer of Intercast Company turned out to be the most stable one to vacuum effect, and detector does not change the sensitivity up to response function REL{sub 200} {approx_equal} 1 MeVxcm{sup 2}xmg{sup -1} in the mentioned experiment conditions. 7 refs.; 3 figs.
Golovchenko, A N;
Tret`yakova, S P
[1]
- Joint Inst. for Nuclear Research, Dubna (Russian Federation). Lab. of Nuclear Reactions
Citation Formats
Golovchenko, A N, and Tret`yakova, S P.
Registration properties of different types of CR-39 in vacuum conditions of irradiation.
JINR: N. p.,
1991.
Web.
Golovchenko, A N, & Tret`yakova, S P.
Registration properties of different types of CR-39 in vacuum conditions of irradiation.
JINR.
Golovchenko, A N, and Tret`yakova, S P.
1991.
"Registration properties of different types of CR-39 in vacuum conditions of irradiation."
JINR.
@misc{etde_10126057,
title = {Registration properties of different types of CR-39 in vacuum conditions of irradiation}
author = {Golovchenko, A N, and Tret`yakova, S P}
abstractNote = {Sensitivity change has been studied of different types of CR-39 detectors (Pershore, Tastrak, Intercast, Ma-ND/{alpha}) in dependence on holding time of detector in vacuum chamber at the residual pressure P {approx_equal} 2x10{sup -2} and {approx_equal} 5x10{sup -3} Pa before their irradiation with alpha particles from thin {sup 238}Pu source and accelerated charged ions with atomic number Z=2-10 and energy of 9.1 MeV/nucleon. Polymer of Intercast Company turned out to be the most stable one to vacuum effect, and detector does not change the sensitivity up to response function REL{sub 200} {approx_equal} 1 MeVxcm{sup 2}xmg{sup -1} in the mentioned experiment conditions. 7 refs.; 3 figs.}
place = {JINR}
year = {1991}
month = {Dec}
}
title = {Registration properties of different types of CR-39 in vacuum conditions of irradiation}
author = {Golovchenko, A N, and Tret`yakova, S P}
abstractNote = {Sensitivity change has been studied of different types of CR-39 detectors (Pershore, Tastrak, Intercast, Ma-ND/{alpha}) in dependence on holding time of detector in vacuum chamber at the residual pressure P {approx_equal} 2x10{sup -2} and {approx_equal} 5x10{sup -3} Pa before their irradiation with alpha particles from thin {sup 238}Pu source and accelerated charged ions with atomic number Z=2-10 and energy of 9.1 MeV/nucleon. Polymer of Intercast Company turned out to be the most stable one to vacuum effect, and detector does not change the sensitivity up to response function REL{sub 200} {approx_equal} 1 MeVxcm{sup 2}xmg{sup -1} in the mentioned experiment conditions. 7 refs.; 3 figs.}
place = {JINR}
year = {1991}
month = {Dec}
}