You need JavaScript to view this

Diagnostics of a multicharged heavy ion beam with the help of microparticle distributed target; Diagnostika puchka mnogozaryadnykh tyazhelykh ionov s pomoshch`yu raspredelennoj misheni iz malykh chastits

Abstract

Experiment with the heavy ion accelerator (U-400 isochronous cyclotron) were made by using a dispersed volume internal target for the ion beam diagnostic development. The target has been prepared in vacuum with microparticles of luminophor or other materials. The dispersal of microparticles dust has been made with the electromechanical microvibrator for a short time interval equal to few seconds. Microparticles have been heated before hand in vacuum to remove residual gas. The investigation results have been shown significant possibilities of the new perturbation diagnostic method. The information about ion coordinates, internal structure, quality of magnetic field compression, ion current magnitude may be presented at a display. 7 refs.; 3 figs.
Authors:
Gul`bekyan, G G; Mel`nikov, V N; [1]  Tsybin, O Yu [2] 
  1. Joint Inst. for Nuclear Research, Dubna (Russian Federation). Lab. of Nuclear Reactions
  2. Leningradskij Politekhnicheskij Inst., Leningrad (Russian Federation)
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
JINR-R-9-91-558
Reference Number:
SCA: 430303; PA: AIX-24:019445; SN: 93000945737
Resource Relation:
Other Information: PBD: 1991
Subject:
43 PARTICLE ACCELERATORS; ARGON 40 BEAMS; BEAM MONITORING; NEON 20 BEAMS; BEAM PROFILES; FLOWSHEETS; FOCUSING; HEAVY IONS; JINR U-400 CYCLOTRON; MASS SPECTROSCOPY; MULTICHARGED IONS; PERFORMANCE; TARGETS; 430303; EXPERIMENTAL FACILITIES AND EQUIPMENT
OSTI ID:
10126039
Research Organizations:
Joint Inst. for Nuclear Research, Dubna (Russian Federation)
Country of Origin:
JINR
Language:
Russian
Other Identifying Numbers:
Other: ON: DE93616560; TRN: RU9207581019445
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
[6] p.
Announcement Date:
Jul 04, 2005

Citation Formats

Gul`bekyan, G G, Mel`nikov, V N, and Tsybin, O Yu. Diagnostics of a multicharged heavy ion beam with the help of microparticle distributed target; Diagnostika puchka mnogozaryadnykh tyazhelykh ionov s pomoshch`yu raspredelennoj misheni iz malykh chastits. JINR: N. p., 1991. Web.
Gul`bekyan, G G, Mel`nikov, V N, & Tsybin, O Yu. Diagnostics of a multicharged heavy ion beam with the help of microparticle distributed target; Diagnostika puchka mnogozaryadnykh tyazhelykh ionov s pomoshch`yu raspredelennoj misheni iz malykh chastits. JINR.
Gul`bekyan, G G, Mel`nikov, V N, and Tsybin, O Yu. 1991. "Diagnostics of a multicharged heavy ion beam with the help of microparticle distributed target; Diagnostika puchka mnogozaryadnykh tyazhelykh ionov s pomoshch`yu raspredelennoj misheni iz malykh chastits." JINR.
@misc{etde_10126039,
title = {Diagnostics of a multicharged heavy ion beam with the help of microparticle distributed target; Diagnostika puchka mnogozaryadnykh tyazhelykh ionov s pomoshch`yu raspredelennoj misheni iz malykh chastits}
author = {Gul`bekyan, G G, Mel`nikov, V N, and Tsybin, O Yu}
abstractNote = {Experiment with the heavy ion accelerator (U-400 isochronous cyclotron) were made by using a dispersed volume internal target for the ion beam diagnostic development. The target has been prepared in vacuum with microparticles of luminophor or other materials. The dispersal of microparticles dust has been made with the electromechanical microvibrator for a short time interval equal to few seconds. Microparticles have been heated before hand in vacuum to remove residual gas. The investigation results have been shown significant possibilities of the new perturbation diagnostic method. The information about ion coordinates, internal structure, quality of magnetic field compression, ion current magnitude may be presented at a display. 7 refs.; 3 figs.}
place = {JINR}
year = {1991}
month = {Dec}
}