Abstract
Mass spectrometric methods for the determination of natural uranium series disequilibrium were reviewed by means of a literature survey. Thermal ionization mass spectrometry (TIMS) has been used for this purpose with satisfactory results, but there were no studies for geological specimens using the newer variant, the Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In spite of problems of sensitivity and reproducibility, a few feasibility studies show that ICP-MS by means of development has potential for certain applications. (au.) (15 refs., 3 figs., 3 tabs.).
Citation Formats
Kumpulainen, H.
Determination of natural uranium series isotope ratios by mass spectrometry; Luonnon uraanisarjan isotooppisuhteiden massaspektrometrinen maeaeritys.
Finland: N. p.,
1993.
Web.
Kumpulainen, H.
Determination of natural uranium series isotope ratios by mass spectrometry; Luonnon uraanisarjan isotooppisuhteiden massaspektrometrinen maeaeritys.
Finland.
Kumpulainen, H.
1993.
"Determination of natural uranium series isotope ratios by mass spectrometry; Luonnon uraanisarjan isotooppisuhteiden massaspektrometrinen maeaeritys."
Finland.
@misc{etde_10125148,
title = {Determination of natural uranium series isotope ratios by mass spectrometry; Luonnon uraanisarjan isotooppisuhteiden massaspektrometrinen maeaeritys}
author = {Kumpulainen, H}
abstractNote = {Mass spectrometric methods for the determination of natural uranium series disequilibrium were reviewed by means of a literature survey. Thermal ionization mass spectrometry (TIMS) has been used for this purpose with satisfactory results, but there were no studies for geological specimens using the newer variant, the Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In spite of problems of sensitivity and reproducibility, a few feasibility studies show that ICP-MS by means of development has potential for certain applications. (au.) (15 refs., 3 figs., 3 tabs.).}
place = {Finland}
year = {1993}
month = {Sep}
}
title = {Determination of natural uranium series isotope ratios by mass spectrometry; Luonnon uraanisarjan isotooppisuhteiden massaspektrometrinen maeaeritys}
author = {Kumpulainen, H}
abstractNote = {Mass spectrometric methods for the determination of natural uranium series disequilibrium were reviewed by means of a literature survey. Thermal ionization mass spectrometry (TIMS) has been used for this purpose with satisfactory results, but there were no studies for geological specimens using the newer variant, the Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In spite of problems of sensitivity and reproducibility, a few feasibility studies show that ICP-MS by means of development has potential for certain applications. (au.) (15 refs., 3 figs., 3 tabs.).}
place = {Finland}
year = {1993}
month = {Sep}
}