You need JavaScript to view this

Performance of dryer hood heat recovery system. A demonstration at Tait Paper, Inverurie (GB)

Abstract

As part of a project to demonstrate `low-energy production` the United Kingdom company, Thomas Tait and Sons (now Tait Paper) installed a totally enclosed hood on a high-capacity, twin-wire, fine-paper machine. The installation of the hood has produced financial savings, at current production rates of 110,000 annual gross tonnes, of Pound 248,000/year. With a capital cost of Pound 419,000 this represents a payback period of 1.7 years. In order to minimise energy costs the hood was provided with additional equipment to extract and recover maximum energy from the hood exhaust air streams. (author).
Publication Date:
Jun 01, 1991
Product Type:
Miscellaneous
Report Number:
GB-399; NP-45
Reference Number:
SCA: 320304; PA: GB-91:052615; SN: 92000675656
Resource Relation:
Other Information: DN: New Practice report produced under the Best Practice programme for the Energy Technology Support Unit, Harwell (GB).; PBD: Jun 1991
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; PAPER INDUSTRY; ENERGY EFFICIENCY; HEAT RECOVERY; FUME HOODS; DRYING; VENTILATION; CAPITALIZED COST; PAYBACK PERIOD; EXHAUST GASES; WASTE HEAT UTILIZATION; PERFORMANCE; DEMONSTRATION PLANTS; 320304; WASTE HEAT RECOVERY AND UTILIZATION
OSTI ID:
10124724
Research Organizations:
Department of Energy, London (United Kingdom). Energy Efficiency Office; Robert Gordon`s Inst. of Tech., Aberdeen (United Kingdom)
Country of Origin:
United Kingdom
Language:
English
Other Identifying Numbers:
Other: ON: DE92777926; TRN: GB9152615
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
GB
Size:
26 p.
Announcement Date:
Jul 04, 2005

Citation Formats

None. Performance of dryer hood heat recovery system. A demonstration at Tait Paper, Inverurie (GB). United Kingdom: N. p., 1991. Web.
None. Performance of dryer hood heat recovery system. A demonstration at Tait Paper, Inverurie (GB). United Kingdom.
None. 1991. "Performance of dryer hood heat recovery system. A demonstration at Tait Paper, Inverurie (GB)." United Kingdom.
@misc{etde_10124724,
title = {Performance of dryer hood heat recovery system. A demonstration at Tait Paper, Inverurie (GB)}
author = {None}
abstractNote = {As part of a project to demonstrate `low-energy production` the United Kingdom company, Thomas Tait and Sons (now Tait Paper) installed a totally enclosed hood on a high-capacity, twin-wire, fine-paper machine. The installation of the hood has produced financial savings, at current production rates of 110,000 annual gross tonnes, of Pound 248,000/year. With a capital cost of Pound 419,000 this represents a payback period of 1.7 years. In order to minimise energy costs the hood was provided with additional equipment to extract and recover maximum energy from the hood exhaust air streams. (author).}
place = {United Kingdom}
year = {1991}
month = {Jun}
}