Abstract
Computer code system and basic data have been investigated for evaluating fluence to dose equivalent conversion factors for photons and neutrons up to 10 GeV. The present work suggested that the conversion factors would be obtained by incorporating effective quality factors of charged particles into the HERMES (High Energy Radiation Monte Carlo Elaborate System) code system. The effective quality factors for charged particles were calculated on the basis of the Q-L relationships specified in the ICRP Publication-60. (author).
Sato, Osamu;
Uehara, Takashi;
Yoshizawa, Nobuaki;
[1]
Iwai, Satoshi;
Tanaka, Shun-ichi
- Mitsubishi Research Inst., Inc., Tokyo (Japan)
Citation Formats
Sato, Osamu, Uehara, Takashi, Yoshizawa, Nobuaki, Iwai, Satoshi, and Tanaka, Shun-ichi.
Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1). Preparation of code system and basic data.
Japan: N. p.,
1992.
Web.
Sato, Osamu, Uehara, Takashi, Yoshizawa, Nobuaki, Iwai, Satoshi, & Tanaka, Shun-ichi.
Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1). Preparation of code system and basic data.
Japan.
Sato, Osamu, Uehara, Takashi, Yoshizawa, Nobuaki, Iwai, Satoshi, and Tanaka, Shun-ichi.
1992.
"Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1). Preparation of code system and basic data."
Japan.
@misc{etde_10123208,
title = {Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1). Preparation of code system and basic data}
author = {Sato, Osamu, Uehara, Takashi, Yoshizawa, Nobuaki, Iwai, Satoshi, and Tanaka, Shun-ichi}
abstractNote = {Computer code system and basic data have been investigated for evaluating fluence to dose equivalent conversion factors for photons and neutrons up to 10 GeV. The present work suggested that the conversion factors would be obtained by incorporating effective quality factors of charged particles into the HERMES (High Energy Radiation Monte Carlo Elaborate System) code system. The effective quality factors for charged particles were calculated on the basis of the Q-L relationships specified in the ICRP Publication-60. (author).}
place = {Japan}
year = {1992}
month = {Sep}
}
title = {Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1). Preparation of code system and basic data}
author = {Sato, Osamu, Uehara, Takashi, Yoshizawa, Nobuaki, Iwai, Satoshi, and Tanaka, Shun-ichi}
abstractNote = {Computer code system and basic data have been investigated for evaluating fluence to dose equivalent conversion factors for photons and neutrons up to 10 GeV. The present work suggested that the conversion factors would be obtained by incorporating effective quality factors of charged particles into the HERMES (High Energy Radiation Monte Carlo Elaborate System) code system. The effective quality factors for charged particles were calculated on the basis of the Q-L relationships specified in the ICRP Publication-60. (author).}
place = {Japan}
year = {1992}
month = {Sep}
}