You need JavaScript to view this

A large silica aerogel Cerenkov counter for SKS

Abstract

A large silica aerogel Cerenkov counter has been constructed as a kaon trigger counter to veto pions of 0.7 GeV/c for experiments studying hypernuclei by ({pi}{sup +}, K{sup +}) reaction with the superconducting kaon spectrometer (SKS) at the KEK 12 GeV proton synchrotron. It features a large single diffusion box with a sensitive area of 140 cm x 120 cm and a thickness of about 40 cm. Special attention was paid to the shape of a reflector in order to achieve uniform efficiency over the sensitive area. Mean photoelectron number N{sub e}-bar = 6 - 7 was obtained for 0.72 GeV/c ({beta} = 0.984) pions with refractive index of 1.06. (author).
Publication Date:
Jun 01, 1993
Product Type:
Technical Report
Report Number:
INS-984
Reference Number:
SCA: 440104; PA: JPN-93:012063; EDB-94:026651; ERA-19:010178; NTS-94:017574; SN: 94001140272
Resource Relation:
Other Information: PBD: Jun 1993
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CHERENKOV COUNTERS; SILICA GEL; TRIGGER CIRCUITS; PIONS; MEV RANGE 100-1000; PHOTOEMISSION; PHOTOMULTIPLIERS; PERFORMANCE; SPATIAL RESOLUTION; MONTE CARLO METHOD; SPECIFICATIONS; KEK SYNCHROTRON; 440104; HIGH ENERGY PHYSICS INSTRUMENTATION
OSTI ID:
10120815
Research Organizations:
Tokyo Univ., Tanashi (Japan). Inst. for Nuclear Study
Country of Origin:
Japan
Language:
English
Other Identifying Numbers:
Other: ON: DE94737841; TRN: JP9312063
Availability:
OSTI; NTIS; INIS
Submitting Site:
JPN
Size:
20 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Hasegawa, T, Hashimoto, O, Nagae, T, and Sekimoto, M. A large silica aerogel Cerenkov counter for SKS. Japan: N. p., 1993. Web.
Hasegawa, T, Hashimoto, O, Nagae, T, & Sekimoto, M. A large silica aerogel Cerenkov counter for SKS. Japan.
Hasegawa, T, Hashimoto, O, Nagae, T, and Sekimoto, M. 1993. "A large silica aerogel Cerenkov counter for SKS." Japan.
@misc{etde_10120815,
title = {A large silica aerogel Cerenkov counter for SKS}
author = {Hasegawa, T, Hashimoto, O, Nagae, T, and Sekimoto, M}
abstractNote = {A large silica aerogel Cerenkov counter has been constructed as a kaon trigger counter to veto pions of 0.7 GeV/c for experiments studying hypernuclei by ({pi}{sup +}, K{sup +}) reaction with the superconducting kaon spectrometer (SKS) at the KEK 12 GeV proton synchrotron. It features a large single diffusion box with a sensitive area of 140 cm x 120 cm and a thickness of about 40 cm. Special attention was paid to the shape of a reflector in order to achieve uniform efficiency over the sensitive area. Mean photoelectron number N{sub e}-bar = 6 - 7 was obtained for 0.72 GeV/c ({beta} = 0.984) pions with refractive index of 1.06. (author).}
place = {Japan}
year = {1993}
month = {Jun}
}