You need JavaScript to view this

Test of the scroll pump in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly. JFCU scroll pump test and result, JFCU stand alone tritium test 2

Abstract

In the JAERI Fuel Cleanup System (JFCU), major subsystem of the TSTA simulated fusion fuel loop, a Normetex Scroll pump is used to pump out hydrogen isotope gases from the palladium diffuser. The characteristics of the pump was measured with hydrogen isotopes and helium, in a closed loop. Compression ratio and ultimate pressure were strongly affected by the delivery pressure and the species of the gas. Particularly with H{sub 2} and D{sub 2}, additional metal bellows pump was proved to be needed to satisfy the process requirement. For hydrogen isotopes, pumping characteristics improves with the mass of the gas and similar pumping capability was obtained with pure T{sub 2} and helium. (author).
Authors:
Hayashi, Takumi; Konishi, Satoshi; [1]  Ohira, Shigeru [2] 
  1. Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment
  2. and others
Publication Date:
Mar 01, 1993
Product Type:
Technical Report
Report Number:
JAERI-M-93-094
Reference Number:
SCA: 700460; PA: JPN-93:012042; EDB-94:027941; ERA-19:011278; NTS-94:017566; SN: 94001140251
Resource Relation:
Other Information: PBD: Mar 1993
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; TRITIUM SYSTEMS TEST ASSEMBLY; D-T REACTORS; TRITIUM; THERMONUCLEAR REACTOR FUELING; VACUUM PUMPS; TRITIUM RECOVERY; DEUTERIUM; PALLADIUM; RECYCLING; 700460; HEATING AND FUELING SYSTEMS; FUELS
OSTI ID:
10120784
Research Organizations:
Japan Atomic Energy Research Inst., Tokyo (Japan)
Country of Origin:
Japan
Language:
English
Other Identifying Numbers:
Other: ON: DE94737820; TRN: JP9312042
Availability:
OSTI; NTIS; INIS
Submitting Site:
JPN
Size:
64 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Hayashi, Takumi, Konishi, Satoshi, and Ohira, Shigeru. Test of the scroll pump in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly. JFCU scroll pump test and result, JFCU stand alone tritium test 2. Japan: N. p., 1993. Web.
Hayashi, Takumi, Konishi, Satoshi, & Ohira, Shigeru. Test of the scroll pump in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly. JFCU scroll pump test and result, JFCU stand alone tritium test 2. Japan.
Hayashi, Takumi, Konishi, Satoshi, and Ohira, Shigeru. 1993. "Test of the scroll pump in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly. JFCU scroll pump test and result, JFCU stand alone tritium test 2." Japan.
@misc{etde_10120784,
title = {Test of the scroll pump in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly. JFCU scroll pump test and result, JFCU stand alone tritium test 2}
author = {Hayashi, Takumi, Konishi, Satoshi, and Ohira, Shigeru}
abstractNote = {In the JAERI Fuel Cleanup System (JFCU), major subsystem of the TSTA simulated fusion fuel loop, a Normetex Scroll pump is used to pump out hydrogen isotope gases from the palladium diffuser. The characteristics of the pump was measured with hydrogen isotopes and helium, in a closed loop. Compression ratio and ultimate pressure were strongly affected by the delivery pressure and the species of the gas. Particularly with H{sub 2} and D{sub 2}, additional metal bellows pump was proved to be needed to satisfy the process requirement. For hydrogen isotopes, pumping characteristics improves with the mass of the gas and similar pumping capability was obtained with pure T{sub 2} and helium. (author).}
place = {Japan}
year = {1993}
month = {Mar}
}