You need JavaScript to view this

Design and construction of a type testing and production test facility for HEPA filters to be installed in ventilation systems of German nuclear power plants; Auslegung und Bau einer Typ- und Serienpruefanlage fuer Filterelemente der Klasse S fuer den Einsatz in Lueftungsanlagen deutscher Kernkraftwerke

Technical Report:

Abstract

High-efficiency particulate air filters (HEPA filters) in nuclear plants frequently constitute part of the last barrier separating potentially contaminated areas from the environment. Their failure may cause radioactive substances to be released. The sensitivity of the filter media employed, and the problems associated with manufacturing the HEPA filters normally used in nuclear plants, result in considerable differences in the quality of commercial HEPA filters. Aging of filter components during operation may greatly reduce the loading capacity of the entire filter. A relatively large number of HEPA filters were found to be defective at the end of service life. In order to be able to guarantee the removal efficiency of HEPA filters over a sufficient length of service life and under accident conditions, quality control measures must be introduced. Type tests of the HEPA filters to be used in nuclear plants must include a number of criteria beyond the loads imposed by the rated volumetric flow rate under the usual room air conditions. These criteria have been combined in a special type test (DIN 25 414), and passing this test should be made a prerequisite for the use of HEPA filters in nuclear plants. In addition, random inspections of production HEPA  More>>
Publication Date:
May 01, 1993
Product Type:
Technical Report
Report Number:
KFK-5149
Reference Number:
SCA: 420200; PA: DEN-94:0F0717; EDB-94:026355; ERA-19:007146; NTS-94:015651; SN: 94001136164
Resource Relation:
Other Information: PBD: May 1993
Subject:
42 ENGINEERING; NUCLEAR POWER PLANTS; AIR FILTERS; AEROSOLS; DROPLETS; MOISTURE; STANDARDS; PERFORMANCE TESTING; AVAILABILITY; PACKINGS; AIR FLOW; FLOW RATE; VENTILATION; 420200; FACILITIES, EQUIPMENT, AND TECHNIQUES
OSTI ID:
10119819
Research Organizations:
Kernforschungszentrum Karlsruhe GmbH (Germany); Kernforschungszentrum Karlsruhe GmbH (Germany). Lab. fuer Aerosolphysik und Filtertechnik (LAF)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Journal ID: ISSN 0303-4003; Other: ON: DE94734058; TRN: DE94F0717
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
43 p.
Announcement Date:
Jun 30, 2005

Technical Report:

Citation Formats

Kuhn, W, Fronhoefer, M, Neuberger, M, and Wilhelm, J. Design and construction of a type testing and production test facility for HEPA filters to be installed in ventilation systems of German nuclear power plants; Auslegung und Bau einer Typ- und Serienpruefanlage fuer Filterelemente der Klasse S fuer den Einsatz in Lueftungsanlagen deutscher Kernkraftwerke. Germany: N. p., 1993. Web.
Kuhn, W, Fronhoefer, M, Neuberger, M, & Wilhelm, J. Design and construction of a type testing and production test facility for HEPA filters to be installed in ventilation systems of German nuclear power plants; Auslegung und Bau einer Typ- und Serienpruefanlage fuer Filterelemente der Klasse S fuer den Einsatz in Lueftungsanlagen deutscher Kernkraftwerke. Germany.
Kuhn, W, Fronhoefer, M, Neuberger, M, and Wilhelm, J. 1993. "Design and construction of a type testing and production test facility for HEPA filters to be installed in ventilation systems of German nuclear power plants; Auslegung und Bau einer Typ- und Serienpruefanlage fuer Filterelemente der Klasse S fuer den Einsatz in Lueftungsanlagen deutscher Kernkraftwerke." Germany.
@misc{etde_10119819,
title = {Design and construction of a type testing and production test facility for HEPA filters to be installed in ventilation systems of German nuclear power plants; Auslegung und Bau einer Typ- und Serienpruefanlage fuer Filterelemente der Klasse S fuer den Einsatz in Lueftungsanlagen deutscher Kernkraftwerke}
author = {Kuhn, W, Fronhoefer, M, Neuberger, M, and Wilhelm, J}
abstractNote = {High-efficiency particulate air filters (HEPA filters) in nuclear plants frequently constitute part of the last barrier separating potentially contaminated areas from the environment. Their failure may cause radioactive substances to be released. The sensitivity of the filter media employed, and the problems associated with manufacturing the HEPA filters normally used in nuclear plants, result in considerable differences in the quality of commercial HEPA filters. Aging of filter components during operation may greatly reduce the loading capacity of the entire filter. A relatively large number of HEPA filters were found to be defective at the end of service life. In order to be able to guarantee the removal efficiency of HEPA filters over a sufficient length of service life and under accident conditions, quality control measures must be introduced. Type tests of the HEPA filters to be used in nuclear plants must include a number of criteria beyond the loads imposed by the rated volumetric flow rate under the usual room air conditions. These criteria have been combined in a special type test (DIN 25 414), and passing this test should be made a prerequisite for the use of HEPA filters in nuclear plants. In addition, random inspections of production HEPA filters should be carried out to allow an adequate standard of quality to be guaranteed for a long time. (orig./GL) [Deutsch] Schwebstoffilterelemente der Klasse S bilden in kerntechnischen Anlagen haeufig einen Teil der letzten Barriere zwischen den moeglicherweise kontaminierten Bereichen und der Umgebung. Ihr Versagen kann zur Freisetzung von radioaktiven Stoffen fuehren. Die Empfindlichkeit der verwendeten Filtermedien und die Problematik der Herstellung der in der Kerntechnik gebraeuchlichen Schwebstoffilter der Klasse S fuehrt zu wesentlichen Unterschieden der Qualitaet der auf dem Markt angebotenen S-Filter. Die waehrend des Betriebes eintretende Alterung der einzelnen Filterbestandteile kann die Belastbarkeit des gesamten Filters erheblich reduzieren. Der Anfall an defekten S-Filtern, der nach Beendigung des betrieblichen Einsatzes festgestellt wurde, ist relativ hoch. Um den von S-Filtern geforderten Abscheidegrad ueber eine ausreichende Betriebszeit und unter Stoerfallbedingungen gewaehrleisten zu koennen, ist eine Qualitaetskontrolle durchzufuehren. Die Typpruefung des in der Kerntechnik einzusetzenden S-Filters muss eine Reihe von Anforderungen einschliessen, die ueber die Belastungen durch den Nennvolumenstrom bei ueblichen Raumluftbedingungen hinausgeht. Diese Anforderungen wurden in einer besonderen Typpruefung (DIN 25 414) zusammengefasst, deren Bestehen zur Voraussetzung fuer den Einsatz von S-Filtern in kerntechnischen Anlagen gemacht werden sollte. Darueber hinaus sollten stichprobenartig Pruefungen einzelner S-Filter aus Produktionsserien durchgefuehrt werden, um einen angemessenen Qualitaetsstandard auf Dauer voraussetzen zu koennen. (orig./GL) Anstroemgeschwindigkeit, sondern im wesentlichen zeitabhaengig. Ein Pruefdifferenzdruck von 5 kPa ueber eine Haltezeit von 4 Stunden in nebelhaltiger Luft wurde festgesetzt. Dieser wurde in Versuchen ermittelt, wobei die geforderte Belastbarkeit der S-Filter entsprechend gueltiger DIN 25414 als Vergleich herangezogen wurde. (orig.)}
place = {Germany}
year = {1993}
month = {May}
}