Simple in design and easy to manufacture DC-SQUIDs with bridge In-Sn contacts are developed. The flux resolution is {approx} 10{Phi}{sub 0}/{radical}Hz and the energy resolution is 1-{sup -29}-10{sup -30}J/Hz at a frequency above 1-2 Hz. The SQUIDs can operate with attached film input coils of 1-{sup -6} H with coupling coefficient 0,4, their characteristics are stable in time and immune to external constant magnetic fields and they can be used in medium-sensitivity magnetometers. 12 refs.; 8 figs.; 2 tabs.
Citation Formats
Golovanev, E A, Sorokin, A M, and Til`chenko, E N.
Stable film squids with bridge contacts of In-Sn alloy; Stabil`nye plenochnye s mostikovymi kontaktami iz splava InSn.
Ukraine: N. p.,
1989.
Web.
Golovanev, E A, Sorokin, A M, & Til`chenko, E N.
Stable film squids with bridge contacts of In-Sn alloy; Stabil`nye plenochnye s mostikovymi kontaktami iz splava InSn.
Ukraine.
Golovanev, E A, Sorokin, A M, and Til`chenko, E N.
1989.
"Stable film squids with bridge contacts of In-Sn alloy; Stabil`nye plenochnye s mostikovymi kontaktami iz splava InSn."
Ukraine.
@misc{etde_10119135,
title = {Stable film squids with bridge contacts of In-Sn alloy; Stabil`nye plenochnye s mostikovymi kontaktami iz splava InSn}
author = {Golovanev, E A, Sorokin, A M, and Til`chenko, E N}
abstractNote = {Simple in design and easy to manufacture DC-SQUIDs with bridge In-Sn contacts are developed. The flux resolution is {approx} 10{Phi}{sub 0}/{radical}Hz and the energy resolution is 1-{sup -29}-10{sup -30}J/Hz at a frequency above 1-2 Hz. The SQUIDs can operate with attached film input coils of 1-{sup -6} H with coupling coefficient 0,4, their characteristics are stable in time and immune to external constant magnetic fields and they can be used in medium-sensitivity magnetometers. 12 refs.; 8 figs.; 2 tabs.}
place = {Ukraine}
year = {1989}
month = {Dec}
}
title = {Stable film squids with bridge contacts of In-Sn alloy; Stabil`nye plenochnye s mostikovymi kontaktami iz splava InSn}
author = {Golovanev, E A, Sorokin, A M, and Til`chenko, E N}
abstractNote = {Simple in design and easy to manufacture DC-SQUIDs with bridge In-Sn contacts are developed. The flux resolution is {approx} 10{Phi}{sub 0}/{radical}Hz and the energy resolution is 1-{sup -29}-10{sup -30}J/Hz at a frequency above 1-2 Hz. The SQUIDs can operate with attached film input coils of 1-{sup -6} H with coupling coefficient 0,4, their characteristics are stable in time and immune to external constant magnetic fields and they can be used in medium-sensitivity magnetometers. 12 refs.; 8 figs.; 2 tabs.}
place = {Ukraine}
year = {1989}
month = {Dec}
}