Magnetic disturbance effects in noise thermometry; Magnetische Stoereffekte in der Rauschthermometrie

Abstract

Due to the very small measurement signals, a compensation process is used, which presupposes undisturbed signals of the measurement resistance and a compensation resistance as necessary conditions. There is a two-channel control for the measurement and compensation circuit, so that parasitic noise voltages from the incoming leads and the electronics can be eliminated by cross-correlation. The sensor which is designed as a combined thermocouple/noise thermometer sensor, permits continuous measurement of temperature by measuring the thermal voltages and the in situ calibration of the thermocouples at all times, which may have considerable drift of the thermal voltages, depending on environmental effects. Leads designed as thermocouples use ferromagnetic materials, in part. (orig./DG). [Deutsch] Aufgrund der sehr kleinen Messsignale wird ein Vergleichsverfahren verwendet, das ungestoerte Signale des Messwiderstandes und eines Vergleichswiderstandes als notwendige Bedingung vorraussetzt. Die Leitungsanordnung erfolgt fuer den Mess- und den Vergleichskreis zweikanalig, damit parasitaere Rauschspannungen der Zuleitungen und der Elektronik durch Kreuzkorrelation eliminiert werden koennen. Der Sensor, der als kombinierter Thermoelement-Rauschthermometer-Fuehler ausgelegt ist, erlaubt die kontinuierliche Temperaturerfassung durch die Messung der Thermospannungen und die jederzeitige in situ Kalibrierung der Thermoelemente, die in Abhaengigkeit von den Umgebungseinfluessen erhebliche Driften der Thermospannungen aufweisen koennen. In diesen als Thermoelemente ausgelegten Zuleitungen kommen zum  More>>
Authors:
Publication Date:
Jan 01, 1992
Product Type:
Thesis/Dissertation
Report Number:
Juel-2574
Reference Number:
SCA: 440500; PA: DEN-93:000973; SN: 93000925082
Resource Relation:
Other Information: TH: Diss.; PBD: Jan 1992
Subject:
47 OTHER INSTRUMENTATION; NOISE THERMOMETERS; THERMOMAGNETISM; THERMOCOUPLES; ELECTRONIC EQUIPMENT; 440500; THERMAL INSTRUMENTATION
OSTI ID:
10116621
Research Organizations:
Forschungszentrum Juelich GmbH (Germany). Zentrallabor fuer Elektronik; Technische Hochschule Aachen (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE93758692; TRN: DE9300973
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
162 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Fischer, M. Magnetic disturbance effects in noise thermometry; Magnetische Stoereffekte in der Rauschthermometrie. Germany: N. p., 1992. Web.
Fischer, M. Magnetic disturbance effects in noise thermometry; Magnetische Stoereffekte in der Rauschthermometrie. Germany.
Fischer, M. 1992. "Magnetic disturbance effects in noise thermometry; Magnetische Stoereffekte in der Rauschthermometrie." Germany.
@misc{etde_10116621,
title = {Magnetic disturbance effects in noise thermometry; Magnetische Stoereffekte in der Rauschthermometrie}
author = {Fischer, M}
abstractNote = {Due to the very small measurement signals, a compensation process is used, which presupposes undisturbed signals of the measurement resistance and a compensation resistance as necessary conditions. There is a two-channel control for the measurement and compensation circuit, so that parasitic noise voltages from the incoming leads and the electronics can be eliminated by cross-correlation. The sensor which is designed as a combined thermocouple/noise thermometer sensor, permits continuous measurement of temperature by measuring the thermal voltages and the in situ calibration of the thermocouples at all times, which may have considerable drift of the thermal voltages, depending on environmental effects. Leads designed as thermocouples use ferromagnetic materials, in part. (orig./DG). [Deutsch] Aufgrund der sehr kleinen Messsignale wird ein Vergleichsverfahren verwendet, das ungestoerte Signale des Messwiderstandes und eines Vergleichswiderstandes als notwendige Bedingung vorraussetzt. Die Leitungsanordnung erfolgt fuer den Mess- und den Vergleichskreis zweikanalig, damit parasitaere Rauschspannungen der Zuleitungen und der Elektronik durch Kreuzkorrelation eliminiert werden koennen. Der Sensor, der als kombinierter Thermoelement-Rauschthermometer-Fuehler ausgelegt ist, erlaubt die kontinuierliche Temperaturerfassung durch die Messung der Thermospannungen und die jederzeitige in situ Kalibrierung der Thermoelemente, die in Abhaengigkeit von den Umgebungseinfluessen erhebliche Driften der Thermospannungen aufweisen koennen. In diesen als Thermoelemente ausgelegten Zuleitungen kommen zum Teil ferromagnetische Materialien zum Einsatz. (orig./DG).}
place = {Germany}
year = {1992}
month = {Jan}
}