You need JavaScript to view this

A study on retrofit measures of KIER buildings for energy conservation

Abstract

Buildings of KIER that were constructed in 1980 consume much energy, because of outworn equipments(boiler, refrigerator, fan coil unit, piping) and windows facing to the west of main research building and irrational operation of H.V.A.C system. The purpose of this study is to present retrofit measures for the improvement of energy performance and indoor environment on KIER building by investigation and testing actual living conditions. From these results, we obtained 27.6% energy saving of heating and cooling load in KIER building. (author). refs., figs., tabs.
Authors:
Park, H S; Yoo, H H; Chang, H J; Chang, M S [1] 
  1. Korea Institute of Energy Research, Taejon (Korea, Republic of)
Publication Date:
Mar 01, 1994
Product Type:
Technical Report
Report Number:
KE-93005B
Reference Number:
SCA: 320100; PA: KR-94:000162; EDB-95:028873; SN: 95001335478
Resource Relation:
Other Information: PBD: Mar 1994
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; BUILDINGS; RETROFITTING; ENERGY CONSERVATION; HEATING; ENERGY EFFICIENCY; COOLING; THERMAL INSULATION; 320100
OSTI ID:
10115703
Research Organizations:
No corporate text available (Country unknown/Code not available)
Country of Origin:
Korea, Republic of
Language:
Korean
Other Identifying Numbers:
Other: ON: DE95744290; TRN: KR9400162
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
KR
Size:
309 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Park, H S, Yoo, H H, Chang, H J, and Chang, M S. A study on retrofit measures of KIER buildings for energy conservation. Korea, Republic of: N. p., 1994. Web.
Park, H S, Yoo, H H, Chang, H J, & Chang, M S. A study on retrofit measures of KIER buildings for energy conservation. Korea, Republic of.
Park, H S, Yoo, H H, Chang, H J, and Chang, M S. 1994. "A study on retrofit measures of KIER buildings for energy conservation." Korea, Republic of.
@misc{etde_10115703,
title = {A study on retrofit measures of KIER buildings for energy conservation}
author = {Park, H S, Yoo, H H, Chang, H J, and Chang, M S}
abstractNote = {Buildings of KIER that were constructed in 1980 consume much energy, because of outworn equipments(boiler, refrigerator, fan coil unit, piping) and windows facing to the west of main research building and irrational operation of H.V.A.C system. The purpose of this study is to present retrofit measures for the improvement of energy performance and indoor environment on KIER building by investigation and testing actual living conditions. From these results, we obtained 27.6% energy saving of heating and cooling load in KIER building. (author). refs., figs., tabs.}
place = {Korea, Republic of}
year = {1994}
month = {Mar}
}