Abstract
A 64 cell low energy electron tracking detector with multiwire drift tubes operating in the Geiger mode and filled with helium is described. Low radioactive materials have been used to build the detector. Data corresponding to 5619 hours in the Frejus Underground Laboratory are presented. Conclusions are drawn for the possibility of using such a detector for a double beta decay experiment.
Blum, D;
Busto, J;
Campagne, J E;
Jullian, S;
Lalanne, D;
Laplanche, F;
Natchez, F;
Szklarz, G;
[1]
Dassie, D;
Hubert, P;
Isaac, M C.P.;
Izac, C;
Leccia, F;
Mennrath, P;
[2]
Longuemare, C;
[3]
Lamhamdi, T;
Linck, I;
Scheibling, F;
[4]
Isaac, M C.P.
[5]
- Paris-11 Univ., 91 - Orsay (France). Lab. de l`Accelerateur Lineaire
- Bordeaux-1 Univ., 33 - Gradignan (France). Centre d`Etudes Nucleaires
- Caen Univ., 14 (France). Lab. de Physique Corpusculaire
- Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires
- Fundacao de Amparo a Pesquisa do Espado, Sao Paulo (BR)
Citation Formats
Blum, D, Busto, J, Campagne, J E, Jullian, S, Lalanne, D, Laplanche, F, Natchez, F, Szklarz, G, Dassie, D, Hubert, P, Isaac, M C.P., Izac, C, Leccia, F, Mennrath, P, Longuemare, C, Lamhamdi, T, Linck, I, Scheibling, F, and Isaac, M C.P.
Double beta decay prototype detector with multiwire drift tubes in the Geiger mode.
France: N. p.,
1991.
Web.
Blum, D, Busto, J, Campagne, J E, Jullian, S, Lalanne, D, Laplanche, F, Natchez, F, Szklarz, G, Dassie, D, Hubert, P, Isaac, M C.P., Izac, C, Leccia, F, Mennrath, P, Longuemare, C, Lamhamdi, T, Linck, I, Scheibling, F, & Isaac, M C.P.
Double beta decay prototype detector with multiwire drift tubes in the Geiger mode.
France.
Blum, D, Busto, J, Campagne, J E, Jullian, S, Lalanne, D, Laplanche, F, Natchez, F, Szklarz, G, Dassie, D, Hubert, P, Isaac, M C.P., Izac, C, Leccia, F, Mennrath, P, Longuemare, C, Lamhamdi, T, Linck, I, Scheibling, F, and Isaac, M C.P.
1991.
"Double beta decay prototype detector with multiwire drift tubes in the Geiger mode."
France.
@misc{etde_10115688,
title = {Double beta decay prototype detector with multiwire drift tubes in the Geiger mode}
author = {Blum, D, Busto, J, Campagne, J E, Jullian, S, Lalanne, D, Laplanche, F, Natchez, F, Szklarz, G, Dassie, D, Hubert, P, Isaac, M C.P., Izac, C, Leccia, F, Mennrath, P, Longuemare, C, Lamhamdi, T, Linck, I, Scheibling, F, and Isaac, M C.P.}
abstractNote = {A 64 cell low energy electron tracking detector with multiwire drift tubes operating in the Geiger mode and filled with helium is described. Low radioactive materials have been used to build the detector. Data corresponding to 5619 hours in the Frejus Underground Laboratory are presented. Conclusions are drawn for the possibility of using such a detector for a double beta decay experiment.}
place = {France}
year = {1991}
month = {Jun}
}
title = {Double beta decay prototype detector with multiwire drift tubes in the Geiger mode}
author = {Blum, D, Busto, J, Campagne, J E, Jullian, S, Lalanne, D, Laplanche, F, Natchez, F, Szklarz, G, Dassie, D, Hubert, P, Isaac, M C.P., Izac, C, Leccia, F, Mennrath, P, Longuemare, C, Lamhamdi, T, Linck, I, Scheibling, F, and Isaac, M C.P.}
abstractNote = {A 64 cell low energy electron tracking detector with multiwire drift tubes operating in the Geiger mode and filled with helium is described. Low radioactive materials have been used to build the detector. Data corresponding to 5619 hours in the Frejus Underground Laboratory are presented. Conclusions are drawn for the possibility of using such a detector for a double beta decay experiment.}
place = {France}
year = {1991}
month = {Jun}
}