You need JavaScript to view this

Christian Michelsen Research (CMR) multiphase flow rig. Reference system uncertainties

Abstract

This document gives a description of the 4 inches multiphase flow loop at Christian Michelsen Research (CMR). The single phase reference measurement system is described, and associated measurement uncertainties are discussed and evaluated. The result is a specification of the uncertainties in reference measurements when using this loop for testing the performance of multiphase flow meters. 11 figs., 2 tabs.
Authors:
Publication Date:
Nov 01, 1992
Product Type:
Technical Report
Report Number:
CMR-92-A15016
Reference Number:
SCA: 022000; 032000; 440800; PA: NW-93:005488; NTS-94:008009; EDB-94:017194; ERA-19:006111; SN: 94001129736
Resource Relation:
Other Information: PBD: Nov 1992
Subject:
02 PETROLEUM; 03 NATURAL GAS; 47 OTHER INSTRUMENTATION; MULTIPHASE FLOW; MEASURING INSTRUMENTS; MEASURING METHODS; FLOWMETERS; FLOW RATE; BENCH-SCALE EXPERIMENTS; EXPERIMENTAL DATA; DATA COVARIANCES; 022000; 032000; 440800; TRANSPORT, HANDLING, AND STORAGE; MISCELLANEOUS INSTRUMENTATION
OSTI ID:
10115176
Research Organizations:
Christian Michelsen Research A/S, Bergen (Norway)
Country of Origin:
Norway
Language:
English
Other Identifying Numbers:
Other: ON: DE94730379; TRN: NO9305488
Availability:
OSTI; NTIS
Submitting Site:
NW
Size:
34 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Hilland, J. Christian Michelsen Research (CMR) multiphase flow rig. Reference system uncertainties. Norway: N. p., 1992. Web.
Hilland, J. Christian Michelsen Research (CMR) multiphase flow rig. Reference system uncertainties. Norway.
Hilland, J. 1992. "Christian Michelsen Research (CMR) multiphase flow rig. Reference system uncertainties." Norway.
@misc{etde_10115176,
title = {Christian Michelsen Research (CMR) multiphase flow rig. Reference system uncertainties}
author = {Hilland, J}
abstractNote = {This document gives a description of the 4 inches multiphase flow loop at Christian Michelsen Research (CMR). The single phase reference measurement system is described, and associated measurement uncertainties are discussed and evaluated. The result is a specification of the uncertainties in reference measurements when using this loop for testing the performance of multiphase flow meters. 11 figs., 2 tabs.}
place = {Norway}
year = {1992}
month = {Nov}
}