Heat transfer in a 125 MWe CFB boiler

Abstract

A heat fluxmeter has been developed to investigate the heat transfer mechanisms inside a furnace of a CFB (circulating fluidized bed), without disturbing the local hydrodynamics. The first results from a 125 MWe CFB provide some trends in flux differences at various locations. (author). 13 refs., 12 figs.
Publication Date:
Mar 01, 1992
Product Type:
Technical Report
Report Number:
EDF-93-NB-00086
Reference Number:
SCA: 200100; PA: FRC-94:000621; EDB-94:012212; NTS-94:008301; ERA-19:006579; SN: 94001122942
Resource Relation:
Other Information: PBD: Mar 1992
Subject:
20 FOSSIL-FUELED POWER PLANTS; FLUIDIZED BED BOILERS; HEAT TRANSFER; CIRCULATING SYSTEMS; FLUXMETERS; FLUIDIZED BEDS; POWER RANGE 100-1000 MW; FRANCE; SIMULATION; 200100; POWER PLANTS AND POWER GENERATION
OSTI ID:
10114307
Research Organizations:
Electricite de France (EDF), 92 - Clamart (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
Other: ON: DE94728745; TRN: FR9400621
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
FR
Size:
12 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Jestin, L, Meyer, P, and Schmitt, G. Heat transfer in a 125 MWe CFB boiler. France: N. p., 1992. Web.
Jestin, L, Meyer, P, & Schmitt, G. Heat transfer in a 125 MWe CFB boiler. France.
Jestin, L, Meyer, P, and Schmitt, G. 1992. "Heat transfer in a 125 MWe CFB boiler." France.
@misc{etde_10114307,
title = {Heat transfer in a 125 MWe CFB boiler}
author = {Jestin, L, Meyer, P, and Schmitt, G}
abstractNote = {A heat fluxmeter has been developed to investigate the heat transfer mechanisms inside a furnace of a CFB (circulating fluidized bed), without disturbing the local hydrodynamics. The first results from a 125 MWe CFB provide some trends in flux differences at various locations. (author). 13 refs., 12 figs.}
place = {France}
year = {1992}
month = {Mar}
}