You need JavaScript to view this

Effect of detector size and position on measured vibration spectra of strings and rods

Abstract

Weight functions of string and rod vibrations are described by standing and travelling wave models. The effects of detector size and position on the measured vibration spectra was investigated, and the main characteristics of the transfer function were calculated by a simple standing wave model. The theoretical results were compared with data from laboratory rod vibration experiments, and with pressure fluctuation spectra obtained at the Paks Nuclear Power Plant. In addition, some fundamental physical consequences can be made using the theory of superposition of travelling waves and their reflection on clamped rod ends. (R.P.) 5 refs.; 10 figs.
Authors:
Lipcsei, S; Kiss, S; Por, G [1] 
  1. Atomic Energy Research Inst., Budapest (Hungary). Dept. of Applied Reactor Physics
Publication Date:
Apr 01, 1993
Product Type:
Technical Report
Report Number:
KFKI-1993-10/G
Reference Number:
SCA: 661300; 210200; PA: AIX-25:007079; EDB-94:015592; ERA-19:007545; NTS-94:015095; SN: 94001126808
Resource Relation:
Other Information: DN: Submitted to Progress in Nuclear Energy.; PBD: Apr 1993
Subject:
71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; MECHANICAL VIBRATIONS; REACTOR STABILITY; POSITION SENSITIVE DETECTORS; RODS; SPECTRA; TRANSFER FUNCTIONS; WIRES; 661300; 210200; OTHER ASPECTS OF PHYSICAL SCIENCE; POWER REACTORS, NONBREEDING, LIGHT-WATER MODERATED, NONBOILING WATER COOLED
OSTI ID:
10113678
Research Organizations:
Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics
Country of Origin:
Hungary
Language:
English
Other Identifying Numbers:
Other: ON: DE94611105; TRN: HU9316207007079
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
17 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Lipcsei, S, Kiss, S, and Por, G. Effect of detector size and position on measured vibration spectra of strings and rods. Hungary: N. p., 1993. Web.
Lipcsei, S, Kiss, S, & Por, G. Effect of detector size and position on measured vibration spectra of strings and rods. Hungary.
Lipcsei, S, Kiss, S, and Por, G. 1993. "Effect of detector size and position on measured vibration spectra of strings and rods." Hungary.
@misc{etde_10113678,
title = {Effect of detector size and position on measured vibration spectra of strings and rods}
author = {Lipcsei, S, Kiss, S, and Por, G}
abstractNote = {Weight functions of string and rod vibrations are described by standing and travelling wave models. The effects of detector size and position on the measured vibration spectra was investigated, and the main characteristics of the transfer function were calculated by a simple standing wave model. The theoretical results were compared with data from laboratory rod vibration experiments, and with pressure fluctuation spectra obtained at the Paks Nuclear Power Plant. In addition, some fundamental physical consequences can be made using the theory of superposition of travelling waves and their reflection on clamped rod ends. (R.P.) 5 refs.; 10 figs.}
place = {Hungary}
year = {1993}
month = {Apr}
}