Abstract
The impurity concentrations in HL-1 were determined by VUV spectroscopy. The absolute calibration of VUV spectrometer by the branching ratio technique and a SITCODE impurity transport code developed in SWIP for interpreting the spectroscopic measurements are described. In order to obtain these results easily on a shot-to-shot basis at the end of each discharge, a simplified fast evaluation method is introduced. The evaluation of the impurity concentrations in HL-1 discharges with and without carbonization, pump limiter and edge polarization are discussed.
Cuixian, Luo;
Kehua, Li;
Yushan, Liu;
Quanming, Wang;
Wenlin, Yuan
[1]
- Southwest Inst. of Physics, Leshan, SC (China)
Citation Formats
Cuixian, Luo, Kehua, Li, Yushan, Liu, Quanming, Wang, and Wenlin, Yuan.
Study of impurity concentrations by VUV spectroscopy on HL-1.
China: N. p.,
1993.
Web.
Cuixian, Luo, Kehua, Li, Yushan, Liu, Quanming, Wang, & Wenlin, Yuan.
Study of impurity concentrations by VUV spectroscopy on HL-1.
China.
Cuixian, Luo, Kehua, Li, Yushan, Liu, Quanming, Wang, and Wenlin, Yuan.
1993.
"Study of impurity concentrations by VUV spectroscopy on HL-1."
China.
@misc{etde_10112856,
title = {Study of impurity concentrations by VUV spectroscopy on HL-1}
author = {Cuixian, Luo, Kehua, Li, Yushan, Liu, Quanming, Wang, and Wenlin, Yuan}
abstractNote = {The impurity concentrations in HL-1 were determined by VUV spectroscopy. The absolute calibration of VUV spectrometer by the branching ratio technique and a SITCODE impurity transport code developed in SWIP for interpreting the spectroscopic measurements are described. In order to obtain these results easily on a shot-to-shot basis at the end of each discharge, a simplified fast evaluation method is introduced. The evaluation of the impurity concentrations in HL-1 discharges with and without carbonization, pump limiter and edge polarization are discussed.}
place = {China}
year = {1993}
month = {Jul}
}
title = {Study of impurity concentrations by VUV spectroscopy on HL-1}
author = {Cuixian, Luo, Kehua, Li, Yushan, Liu, Quanming, Wang, and Wenlin, Yuan}
abstractNote = {The impurity concentrations in HL-1 were determined by VUV spectroscopy. The absolute calibration of VUV spectrometer by the branching ratio technique and a SITCODE impurity transport code developed in SWIP for interpreting the spectroscopic measurements are described. In order to obtain these results easily on a shot-to-shot basis at the end of each discharge, a simplified fast evaluation method is introduced. The evaluation of the impurity concentrations in HL-1 discharges with and without carbonization, pump limiter and edge polarization are discussed.}
place = {China}
year = {1993}
month = {Jul}
}