You need JavaScript to view this

Driving of the laser beam in the calibration system of the jet chamber of the OPAL detector; Steuerung des Laserstrahls im Kalibrationssystem der Jetkammer des OPAL-Detektors

Abstract

The OPAL jet chamer is calibrated by means of UV-Laser beams. A complex optical system containing 226 mirrors has been set up to guide the beams into the chamber. The distance between Laser and chamber is about 16 m and the beams have to be positioned in the chamber with an accuracy better than 0.5 mm. The beam position is measured by 96 Lateral Effect Diodes with a spatial resolution of about 80 {mu}m and controlled by microcomputer systems (VME) which steer 4 movable mirrors with a precision of 5 {mu}m. A control program has been tested first with a simulation of the Laser calibration system. It operates successfully since LEP start. Stability has been investigated - especially the independence of the control program on critical mechanical parameters. (orig.). [Deutsch] In dieser Arbeit werden der Aufbau und die Tests zur Steuerung der Laserstrahlen im Kalibrationssystem der OPAL-Jetkammer beschrieben. Zur Kalibration der OPAL-Jetkammer werden UV-Laserstrahlen eingesetzt. Dazu werden Nd:YAG-Laser ({lambda} = 1064 nm, frequenzvervierfacht auf {lambda} = 266 nm) im gepulsten Modus eingesetzt. Die Pulsdauer betraegt 3 ns, die Wiederholungsrate (Schussrate) ist 5 Hz. Die UV-Strahlen werden mit einem komplizierten Spiegelsystem beidseitig in die Jetkammer geleitet. Vor Eintritt in die Kammer  More>>
Authors:
Publication Date:
Jun 01, 1990
Product Type:
Thesis/Dissertation
Report Number:
BONN-IR-90-31
Reference Number:
SCA: 440104; PA: DEN-92:000703; SN: 92000645582
Resource Relation:
Other Information: TH: Diploma Thesis; PBD: Jun 1990
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; LEP STORAGE RINGS; DRIFT CHAMBERS; CALIBRATION; BEAM POSITION; BEAM TRANSPORT; PHOTON BEAMS; LASER RADIATION; SOLID STATE LASERS; PHOTODIODES; SPATIAL RESOLUTION; BEAM MONITORING; ACCURACY; REMOTE CONTROL; STABILITY; COMPUTER CODES; OPTICAL SYSTEMS; MIRRORS; NEAR ULTRAVIOLET RADIATION; 440104; HIGH ENERGY PHYSICS INSTRUMENTATION
OSTI ID:
10112709
Research Organizations:
Bonn Univ. (Germany). Physikalisches Inst.; Bonn Univ. (Germany). Mathematisch-Naturwissenschaftliche Fakultaet
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE92759284; TRN: DE9200703
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
54 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Neumann, H. Driving of the laser beam in the calibration system of the jet chamber of the OPAL detector; Steuerung des Laserstrahls im Kalibrationssystem der Jetkammer des OPAL-Detektors. Germany: N. p., 1990. Web.
Neumann, H. Driving of the laser beam in the calibration system of the jet chamber of the OPAL detector; Steuerung des Laserstrahls im Kalibrationssystem der Jetkammer des OPAL-Detektors. Germany.
Neumann, H. 1990. "Driving of the laser beam in the calibration system of the jet chamber of the OPAL detector; Steuerung des Laserstrahls im Kalibrationssystem der Jetkammer des OPAL-Detektors." Germany.
@misc{etde_10112709,
title = {Driving of the laser beam in the calibration system of the jet chamber of the OPAL detector; Steuerung des Laserstrahls im Kalibrationssystem der Jetkammer des OPAL-Detektors}
author = {Neumann, H}
abstractNote = {The OPAL jet chamer is calibrated by means of UV-Laser beams. A complex optical system containing 226 mirrors has been set up to guide the beams into the chamber. The distance between Laser and chamber is about 16 m and the beams have to be positioned in the chamber with an accuracy better than 0.5 mm. The beam position is measured by 96 Lateral Effect Diodes with a spatial resolution of about 80 {mu}m and controlled by microcomputer systems (VME) which steer 4 movable mirrors with a precision of 5 {mu}m. A control program has been tested first with a simulation of the Laser calibration system. It operates successfully since LEP start. Stability has been investigated - especially the independence of the control program on critical mechanical parameters. (orig.). [Deutsch] In dieser Arbeit werden der Aufbau und die Tests zur Steuerung der Laserstrahlen im Kalibrationssystem der OPAL-Jetkammer beschrieben. Zur Kalibration der OPAL-Jetkammer werden UV-Laserstrahlen eingesetzt. Dazu werden Nd:YAG-Laser ({lambda} = 1064 nm, frequenzvervierfacht auf {lambda} = 266 nm) im gepulsten Modus eingesetzt. Die Pulsdauer betraegt 3 ns, die Wiederholungsrate (Schussrate) ist 5 Hz. Die UV-Strahlen werden mit einem komplizierten Spiegelsystem beidseitig in die Jetkammer geleitet. Vor Eintritt in die Kammer werden die Strahlen mit Strahlteilern in Doppelstrahlen mit genau bekannten Abstaenden und Divergenzen aufgespalten. Fuer Praezisionsmessungen der Kalibrationsgroessen (wie z.B. die Driftgeschwindigkeit und die verschiedenen Zeitnullpunkte) ist eine praezise Steuerung der Laserstrahlen notwendig. Dazu werden die Strahllagen mit jeweils 2 Positionsmonitoren fuer jeden der 48 Strahlwege auf wenige {mu}m genau gemessen und mit dem Superspiegel gesteuert. Die Ortsinformation (RMS der Ortsverteilung {approx_equal} 80 {mu}m) dieser Positionsmonitore ist nicht linear. (orig./HSI).}
place = {Germany}
year = {1990}
month = {Jun}
}