You need JavaScript to view this

The data acquisition system PHON for the detectors of the PHOENICS experiment; Das Datenerfassungssystem PHON fuer die Detektoren des PHOENICS-Experiments

Thesis/Dissertation:

Abstract

The PHON data acquisition system for the PHOENICS experiment at the stretcher ring ELSA in Bonn and its development is described. PHON is based on a fast parallel CAMAC readout with VME front-end processors and a VAX/VMS computer, allowing c omfortable control and programming. The current configuration of the PHON system at the PHOENICS detector uses two CAMAC branches that are read out in parallel. The data is transferred to the VAX by either the ethernet (max. rate 100 kByte/sec) or a bus coupler device (max. rate 650 kByte/sec). On the VAX the data can be stored on a harddisk and analyzed by several PHON online tasks. The harddisk limits the maximum data rate to a value of approximately 180 kByte/sec. The maximum trigger rate achieved is about 150 Hz. Two kinds of user shells are realized to control the PHON system. A command shell follows the standard of the control language of the VMS operating system and a graphic user interface uses the `X Window System`. The modular structure of the PHON system and the unique kind of creation of all PHON programs makes a further development of the system easy to do. (orig.). [Deutsch] Die vorliegende Arbeit beschreibt  More>>
Authors:
Publication Date:
Jul 01, 1991
Product Type:
Thesis/Dissertation
Report Number:
BONN-IR-91-43
Reference Number:
SCA: 440104; PA: DEN-92:000697; SN: 92000645576
Resource Relation:
Other Information: TH: Diss. Thesis; PBD: Jul 1991
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; DATA ACQUISITION SYSTEMS; PARALLEL PROCESSING; BONN SYNCHROTRON; DEC COMPUTERS; PROCESS COMPUTERS; READOUT SYSTEMS; CAMAC SYSTEM; DATA TRANSMISSION; ON-LINE MEASUREMENT SYSTEMS; MAGNETIC DISKS; REMOTE CONTROL; COMPUTER-GRAPHICS DEVICES; INTERACTIVE DISPLAY DEVICES; DRIFT CHAMBERS; MODULAR STRUCTURES; TRIGGER CIRCUITS; LOGIC CIRCUITS; COMPUTER CODES; PHOTOPRODUCTION; PROTON-PROTON INTERACTIONS; MEV RANGE 100-1000; DEUTERIUM TARGET; HELIUM 3 TARGET; PHOTONUCLEAR REACTIONS; COMPUTER GRAPHICS; 440104; HIGH ENERGY PHYSICS INSTRUMENTATION
OSTI ID:
10112691
Research Organizations:
Bonn Univ. (Germany). Physikalisches Inst.; Bonn Univ. (Germany). Mathematisch-Naturwissenschaftliche Fakultaet
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE92759278; TRN: DE9200697
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
70 p.
Announcement Date:
Jun 30, 2005

Thesis/Dissertation:

Citation Formats

Schneider, W. The data acquisition system PHON for the detectors of the PHOENICS experiment; Das Datenerfassungssystem PHON fuer die Detektoren des PHOENICS-Experiments. Germany: N. p., 1991. Web.
Schneider, W. The data acquisition system PHON for the detectors of the PHOENICS experiment; Das Datenerfassungssystem PHON fuer die Detektoren des PHOENICS-Experiments. Germany.
Schneider, W. 1991. "The data acquisition system PHON for the detectors of the PHOENICS experiment; Das Datenerfassungssystem PHON fuer die Detektoren des PHOENICS-Experiments." Germany.
@misc{etde_10112691,
title = {The data acquisition system PHON for the detectors of the PHOENICS experiment; Das Datenerfassungssystem PHON fuer die Detektoren des PHOENICS-Experiments}
author = {Schneider, W}
abstractNote = {The PHON data acquisition system for the PHOENICS experiment at the stretcher ring ELSA in Bonn and its development is described. PHON is based on a fast parallel CAMAC readout with VME front-end processors and a VAX/VMS computer, allowing c omfortable control and programming. The current configuration of the PHON system at the PHOENICS detector uses two CAMAC branches that are read out in parallel. The data is transferred to the VAX by either the ethernet (max. rate 100 kByte/sec) or a bus coupler device (max. rate 650 kByte/sec). On the VAX the data can be stored on a harddisk and analyzed by several PHON online tasks. The harddisk limits the maximum data rate to a value of approximately 180 kByte/sec. The maximum trigger rate achieved is about 150 Hz. Two kinds of user shells are realized to control the PHON system. A command shell follows the standard of the control language of the VMS operating system and a graphic user interface uses the `X Window System`. The modular structure of the PHON system and the unique kind of creation of all PHON programs makes a further development of the system easy to do. (orig.). [Deutsch] Die vorliegende Arbeit beschreibt die Entwicklung und Funktion des Datenerfassungssystems PHON. Das System basiert auf einer parallelen Auslese von CAMAC-Branchen mit VME-Front-End-Prozessoren und einem VAX/VMS-Hauptrechner, der eine komfortable Programmsteuerung und -Entwicklung erlaubt. Momentan werden an dem PHOENICS-Detektor zwei CAMAC-Branche von jeweils einem VME-Front-End-Prozessor ausgelesen. Die Daten koennen wahlweise ueber Ethernet (max. Uebertragungsrate ca. 100 kByte/sec), oder ueber einen Buskoppler (max. 650 kByte/sec) auf den Hauptrechner (VAXStation 3200) transferiert werden. Dort koennen sie auf einer Festplatte abgespeichert und von verschiedenen Analyseprozessen verarbeitet werden. In dieser Konfiguration werden Datenraten von 180 kByte/sec erzielt. Die maximale Triggerrate betraegt etwa 150 Hz. Die Steuerung des PHON-Systems erfolgt ausschliesslich auf dem komfortablen Hauptrechner. Als Benutzeroberflaechen stehen eine Kommandooberflaeche und eine Grahikoberflaeche zur Verfuegung. Die Kommandooberflaeche lehnt sich an die Kommandosprache des VMS-Betriebssystems DCL (Digital Control Language) an. Die Graphikoberflaeche verwendet das `X Window System`. Durch den modularen Aufbau des Systems und die einheitliche Methode der Erzeugung aller PHON-Programme ist eine einfache Moeglichkeit der Weiterentwicklung von PHON gewaehrleistet. Dadurch kann die Software sowohl an neue Komponenten der PHOENICS-Detektoren angepasst werden, als auch in andere Systeme integriert werden. (orig.).}
place = {Germany}
year = {1991}
month = {Jul}
}