Abstract
Ac loss measurements have been performed in samples of a prototype conductor being developed for application in the central solenoid of NET. Two types of losses have been measured: hysteresis losses in the strand, and coupling losses in the strand, subcables and full size conductor. (H.W.). 1 ref.; 12 figs.; 17 tabs.
Citation Formats
Eikelboom, J A.
Measurements of ac losses in NET prototype OH conductors.
Netherlands: N. p.,
1991.
Web.
Eikelboom, J A.
Measurements of ac losses in NET prototype OH conductors.
Netherlands.
Eikelboom, J A.
1991.
"Measurements of ac losses in NET prototype OH conductors."
Netherlands.
@misc{etde_10111747,
title = {Measurements of ac losses in NET prototype OH conductors}
author = {Eikelboom, J A}
abstractNote = {Ac loss measurements have been performed in samples of a prototype conductor being developed for application in the central solenoid of NET. Two types of losses have been measured: hysteresis losses in the strand, and coupling losses in the strand, subcables and full size conductor. (H.W.). 1 ref.; 12 figs.; 17 tabs.}
place = {Netherlands}
year = {1991}
month = {Mar}
}
title = {Measurements of ac losses in NET prototype OH conductors}
author = {Eikelboom, J A}
abstractNote = {Ac loss measurements have been performed in samples of a prototype conductor being developed for application in the central solenoid of NET. Two types of losses have been measured: hysteresis losses in the strand, and coupling losses in the strand, subcables and full size conductor. (H.W.). 1 ref.; 12 figs.; 17 tabs.}
place = {Netherlands}
year = {1991}
month = {Mar}
}