You need JavaScript to view this

Nuclear design report for yonggwang nuclear power plant unit 1, cycle 7

Abstract

This report presents nuclear design calculations for Cycle 7 of Yonggwang Unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 64 KOFA`s enriched by nominally 3.70 w/o U235. Among the KOFA`s, 36 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 7 amounts to 360 EFPD corresponding to a cycle burnup of 14470 MWD/MTU. (Author).
Authors:
Baik, Joo Hyun; Kwon, Tae Je; Park, Sang Yoon; Song, Jae Woong [1] 
  1. Korea Atomic Energy Res. Inst., Taejon (Korea, Republic of)
Publication Date:
Jul 01, 1992
Product Type:
Technical Report
Report Number:
KAERI/TR-297/92
Reference Number:
SCA: 210200; 220000; PA: AIX-25:003331; EDB-94:012355; ERA-19:003576; NTS-94:014760; SN: 93001120617
Resource Relation:
Other Information: PBD: Jul 1992
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; 22 GENERAL STUDIES OF NUCLEAR REACTORS; REACTOR FUELING; CONTROL ELEMENTS; CONTROL ROD WORTHS; ENGINEERING DRAWINGS; FUEL ASSEMBLIES; POWER DENSITY; POWER DISTRIBUTION; REACTIVITY COEFFICIENTS; 210200; 220000; POWER REACTORS, NONBREEDING, LIGHT-WATER MODERATED, NONBOILING WATER COOLED; NUCLEAR REACTOR TECHNOLOGY
OSTI ID:
10109656
Research Organizations:
Korea Atomic Energy Research Inst., Daeduk (Korea, Republic of)
Country of Origin:
Korea, Republic of
Language:
English
Other Identifying Numbers:
Other: ON: DE94609261; TRN: KR9300139003331
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
123 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Baik, Joo Hyun, Kwon, Tae Je, Park, Sang Yoon, and Song, Jae Woong. Nuclear design report for yonggwang nuclear power plant unit 1, cycle 7. Korea, Republic of: N. p., 1992. Web.
Baik, Joo Hyun, Kwon, Tae Je, Park, Sang Yoon, & Song, Jae Woong. Nuclear design report for yonggwang nuclear power plant unit 1, cycle 7. Korea, Republic of.
Baik, Joo Hyun, Kwon, Tae Je, Park, Sang Yoon, and Song, Jae Woong. 1992. "Nuclear design report for yonggwang nuclear power plant unit 1, cycle 7." Korea, Republic of.
@misc{etde_10109656,
title = {Nuclear design report for yonggwang nuclear power plant unit 1, cycle 7}
author = {Baik, Joo Hyun, Kwon, Tae Je, Park, Sang Yoon, and Song, Jae Woong}
abstractNote = {This report presents nuclear design calculations for Cycle 7 of Yonggwang Unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 64 KOFA`s enriched by nominally 3.70 w/o U235. Among the KOFA`s, 36 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 7 amounts to 360 EFPD corresponding to a cycle burnup of 14470 MWD/MTU. (Author).}
place = {Korea, Republic of}
year = {1992}
month = {Jul}
}