You need JavaScript to view this

Raman spectroscopic investigation of the formation of Mg(HCO{sub 3}){sub 2} used for column regeneration in the MARIX process; Ramanspektroskopische Untersuchungen zur Bildung des im MARIX-Prozess verwendeten Regenerationsmittels Mg(HCO{sub 3}){sub 2}

Abstract

The suitability of a laser Raman spectrometer equipped with optical fibers for remote process control was demonstrated following the reaction of MgO, H{sub 2}O and CO{sub 2} under pressure forming Mg(HCO{sub 3}){sub 2} which is used as reagent for column regeneration in the MARIX process. The dissolution of MgO at different CO{sub 2} pressures was followed with time measuring the resultant Raman spectra, and in the same manner also the precipitation and redissolution behaviour of nesquehonite (aqueous MgCO{sub 3}) was studied which is precipitated from solutions containing Mg(HCO{sub 3}){sub 2} under normal pressure. In addition, equilibrium concentrations of bicarbonate formed at different CO{sub 2} pressures were determined using the same analytical technique, and the results were compared with computed data. (orig.). [Deutsch] Die Eignung eines fuer remote-Messungen mit Lichtleitern ausgelegten Laser-Raman-Spektrometers fuer die Zwecke der in-line-Prozessueberwachung wurde am Beispiel der Erzeugung des im MARIX-Prozess als Regenerationsmittel eingesetzten Mg(HCO{sub 3}){sub 2} demonstriert, das aus MgO, Wasser und CO{sub 2} unter Druck erhalten wird. Neben der Verfolgung des zeitlichen Ablaufs dieser Reaktion bei verschiedenen CO{sub 2}-Druecken und der Messung der dabei resultierenden Ramanspektren wurde in gleicher Weise auch das Faellungs- und Loeseverhalten von wasserhaltigem MgCO{sub 3} (Nesquehonit) untersucht, das beim Entspannen der  More>>
Publication Date:
Aug 01, 1991
Product Type:
Technical Report
Report Number:
KFK-4919
Reference Number:
SCA: 400201; 320305; 320604; PA: DE-92:000114; SN: 92000629730
Resource Relation:
Other Information: PBD: Aug 1991
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; RAMAN SPECTROSCOPY; PROCESS CONTROL; MAGNESIUM CARBONATES; CHEMICAL PREPARATION; REMOTE HANDLING EQUIPMENT; SPECTROMETERS; ION EXCHANGE; REGENERATION; ACID CARBONATES; CARBON DIOXIDE; EQUILIBRIUM; MEDIUM PRESSURE; DIAGRAMS; MAGNESIUM OXIDES; 400201; 320305; 320604; CHEMICAL AND PHYSICOCHEMICAL PROPERTIES; INDUSTRIAL WASTE MANAGEMENT; MUNICIPAL WASTE MANAGEMENT
OSTI ID:
10109571
Research Organizations:
Kernforschungszentrum Karlsruhe GmbH (Germany). Inst. fuer Radiochemie; Kernforschungszentrum Karlsruhe GmbH (Germany). Projekt Schadstoffbeherrschung in der Umwelt (PSU)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE92750159; TRN: DE9200114
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
DE
Size:
21 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Gantner, E, and Steinert, D. Raman spectroscopic investigation of the formation of Mg(HCO{sub 3}){sub 2} used for column regeneration in the MARIX process; Ramanspektroskopische Untersuchungen zur Bildung des im MARIX-Prozess verwendeten Regenerationsmittels Mg(HCO{sub 3}){sub 2}. Germany: N. p., 1991. Web.
Gantner, E, & Steinert, D. Raman spectroscopic investigation of the formation of Mg(HCO{sub 3}){sub 2} used for column regeneration in the MARIX process; Ramanspektroskopische Untersuchungen zur Bildung des im MARIX-Prozess verwendeten Regenerationsmittels Mg(HCO{sub 3}){sub 2}. Germany.
Gantner, E, and Steinert, D. 1991. "Raman spectroscopic investigation of the formation of Mg(HCO{sub 3}){sub 2} used for column regeneration in the MARIX process; Ramanspektroskopische Untersuchungen zur Bildung des im MARIX-Prozess verwendeten Regenerationsmittels Mg(HCO{sub 3}){sub 2}." Germany.
@misc{etde_10109571,
title = {Raman spectroscopic investigation of the formation of Mg(HCO{sub 3}){sub 2} used for column regeneration in the MARIX process; Ramanspektroskopische Untersuchungen zur Bildung des im MARIX-Prozess verwendeten Regenerationsmittels Mg(HCO{sub 3}){sub 2}}
author = {Gantner, E, and Steinert, D}
abstractNote = {The suitability of a laser Raman spectrometer equipped with optical fibers for remote process control was demonstrated following the reaction of MgO, H{sub 2}O and CO{sub 2} under pressure forming Mg(HCO{sub 3}){sub 2} which is used as reagent for column regeneration in the MARIX process. The dissolution of MgO at different CO{sub 2} pressures was followed with time measuring the resultant Raman spectra, and in the same manner also the precipitation and redissolution behaviour of nesquehonite (aqueous MgCO{sub 3}) was studied which is precipitated from solutions containing Mg(HCO{sub 3}){sub 2} under normal pressure. In addition, equilibrium concentrations of bicarbonate formed at different CO{sub 2} pressures were determined using the same analytical technique, and the results were compared with computed data. (orig.). [Deutsch] Die Eignung eines fuer remote-Messungen mit Lichtleitern ausgelegten Laser-Raman-Spektrometers fuer die Zwecke der in-line-Prozessueberwachung wurde am Beispiel der Erzeugung des im MARIX-Prozess als Regenerationsmittel eingesetzten Mg(HCO{sub 3}){sub 2} demonstriert, das aus MgO, Wasser und CO{sub 2} unter Druck erhalten wird. Neben der Verfolgung des zeitlichen Ablaufs dieser Reaktion bei verschiedenen CO{sub 2}-Druecken und der Messung der dabei resultierenden Ramanspektren wurde in gleicher Weise auch das Faellungs- und Loeseverhalten von wasserhaltigem MgCO{sub 3} (Nesquehonit) untersucht, das beim Entspannen der Mg(HCO{sub 3}){sub 2}-Loesungen ausfaellt. Ausserdem wurden mit der gleichen Messmethode die bei verschiedenen CO{sub 2}-Druecken sich einstellenden Gleichgewichtskonzentrationen an Bikarbonat bestimmt und mit rechnerisch ermittelten Daten verglichen. (orig.).}
place = {Germany}
year = {1991}
month = {Aug}
}