Abstract
The construction of magnetic coil system for a 35 GHz gyrotron is reported in great detail. This system is designed to generate a magnetic induction of 13,2 kG over an extension of 13 cm. By using an operating current of about 100 A, it was verified that both the axial magnetic field profile and the spatial non-uniformity are in close agreement with those theoretically predicted. (author).
Citation Formats
Rossi, J O, Aso, Y, Castro, P J, Barroso, J J, Ludwig, G O, Montes, A, Nono, M C.A., and Correa, R A.
Construction of a 13 kG magnetic coil system; Construcao de um sistema de bobinas magneticas de 13 kG.
Brazil: N. p.,
1991.
Web.
Rossi, J O, Aso, Y, Castro, P J, Barroso, J J, Ludwig, G O, Montes, A, Nono, M C.A., & Correa, R A.
Construction of a 13 kG magnetic coil system; Construcao de um sistema de bobinas magneticas de 13 kG.
Brazil.
Rossi, J O, Aso, Y, Castro, P J, Barroso, J J, Ludwig, G O, Montes, A, Nono, M C.A., and Correa, R A.
1991.
"Construction of a 13 kG magnetic coil system; Construcao de um sistema de bobinas magneticas de 13 kG."
Brazil.
@misc{etde_10109012,
title = {Construction of a 13 kG magnetic coil system; Construcao de um sistema de bobinas magneticas de 13 kG}
author = {Rossi, J O, Aso, Y, Castro, P J, Barroso, J J, Ludwig, G O, Montes, A, Nono, M C.A., and Correa, R A}
abstractNote = {The construction of magnetic coil system for a 35 GHz gyrotron is reported in great detail. This system is designed to generate a magnetic induction of 13,2 kG over an extension of 13 cm. By using an operating current of about 100 A, it was verified that both the axial magnetic field profile and the spatial non-uniformity are in close agreement with those theoretically predicted. (author).}
place = {Brazil}
year = {1991}
month = {Aug}
}
title = {Construction of a 13 kG magnetic coil system; Construcao de um sistema de bobinas magneticas de 13 kG}
author = {Rossi, J O, Aso, Y, Castro, P J, Barroso, J J, Ludwig, G O, Montes, A, Nono, M C.A., and Correa, R A}
abstractNote = {The construction of magnetic coil system for a 35 GHz gyrotron is reported in great detail. This system is designed to generate a magnetic induction of 13,2 kG over an extension of 13 cm. By using an operating current of about 100 A, it was verified that both the axial magnetic field profile and the spatial non-uniformity are in close agreement with those theoretically predicted. (author).}
place = {Brazil}
year = {1991}
month = {Aug}
}