You need JavaScript to view this

Contribution to improvements in the analysis of extremely small trace amounts of platinum metals in biotic and ecologically relevant materials. Follow-up project. Final report; Beitrag zur Verbesserung der extremen Spurenanalyse der Platinmetalle in biotischen und umweltrelevanten Materialien. Anschlussvorhaben. Schlussbericht

Abstract

Different decomposition processes for the determination of platinum (adsorptive voltammetry, graphite furnace atomic absorption spectrometry) in biotic and ecologically relevant materials were tested. High-pressure decomposition in quartz vessels (max. 320 C and 130 bar) proved suitable for most sample types whereas open processes can only be recommended for single materials and small sample amounts. Radiochemical tracer-methods were used for testing decomposition, separation and concentration processes for determination of trace amounts of platinum. Studies were performed on ionic chromatographic methods, in particular on electrochemical detection. In-depth research was done into platinum species analysis for the example of grass samples that were either uncontaminated or contaminated with platinum. Platinum levels were determined in various biotic and ecologically relevant materials (uncontaminated and contaminated), especially in body fluids, air-borne particles, soils, fuels, water. (orig.) [Deutsch] Verschiedene Aufschlussmethoden zur Bestimmung von Platin (adsorptive Voltammetrie, Graphitofen-Atomabsorptionsspektrometrie nach Abtrennung und Anreicherung, Ionenchromatographie) in biotischen und umweltrelevanten Materialien wurden getestet. Als geeignet erwies sich fuer die meisten Probenarten der Hochdruckaufschluss in Quarzgefaessen (max. 320 C und 130 bar), waehrend der offene Aufschluss nur fuer einfache Materialien und kleine Probenmengen zu empfehlen ist. Radiochemische Tracer-Methoden wurde zur Ueberpruefung von Aufschlussmethoden und Trenn- und Anreicherungsmethoden zur Bestimmung von Platin im  More>>
Publication Date:
Dec 31, 1993
Product Type:
Technical Report
Report Number:
ETDE/DE-mf-95733294
Reference Number:
SCA: 400102; PA: DE-94:0GP896; EDB-95:023627; SN: 95001314882
Resource Relation:
Other Information: PBD: 1993
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; PLATINUM; TRACE AMOUNTS; ENVIRONMENTAL MATERIALS; QUANTITATIVE CHEMICAL ANALYSIS; SAMPLE PREPARATION; ION EXCHANGE CHROMATOGRAPHY; DUSTS; AIR POLLUTION MONITORING; ABSORPTION SPECTROSCOPY; VOLTAMETRY; AMPEROMETRY; 400102; CHEMICAL AND SPECTRAL PROCEDURES
Sponsoring Organizations:
Bundesministerium fuer Forschung und Technologie, Bonn (Germany)
OSTI ID:
10108629
Research Organizations:
Institut fuer Spektrochemie und Angewandte Spektroskopie (ISAS), Dortmund (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE95733294; CNN: Foerderkennzeichen BMFT 07VPT01A; TRN: DE94GP896
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
DE
Size:
113 p.
Announcement Date:
Jun 30, 2005

Citation Formats

None. Contribution to improvements in the analysis of extremely small trace amounts of platinum metals in biotic and ecologically relevant materials. Follow-up project. Final report; Beitrag zur Verbesserung der extremen Spurenanalyse der Platinmetalle in biotischen und umweltrelevanten Materialien. Anschlussvorhaben. Schlussbericht. Germany: N. p., 1993. Web.
None. Contribution to improvements in the analysis of extremely small trace amounts of platinum metals in biotic and ecologically relevant materials. Follow-up project. Final report; Beitrag zur Verbesserung der extremen Spurenanalyse der Platinmetalle in biotischen und umweltrelevanten Materialien. Anschlussvorhaben. Schlussbericht. Germany.
None. 1993. "Contribution to improvements in the analysis of extremely small trace amounts of platinum metals in biotic and ecologically relevant materials. Follow-up project. Final report; Beitrag zur Verbesserung der extremen Spurenanalyse der Platinmetalle in biotischen und umweltrelevanten Materialien. Anschlussvorhaben. Schlussbericht." Germany.
@misc{etde_10108629,
title = {Contribution to improvements in the analysis of extremely small trace amounts of platinum metals in biotic and ecologically relevant materials. Follow-up project. Final report; Beitrag zur Verbesserung der extremen Spurenanalyse der Platinmetalle in biotischen und umweltrelevanten Materialien. Anschlussvorhaben. Schlussbericht}
author = {None}
abstractNote = {Different decomposition processes for the determination of platinum (adsorptive voltammetry, graphite furnace atomic absorption spectrometry) in biotic and ecologically relevant materials were tested. High-pressure decomposition in quartz vessels (max. 320 C and 130 bar) proved suitable for most sample types whereas open processes can only be recommended for single materials and small sample amounts. Radiochemical tracer-methods were used for testing decomposition, separation and concentration processes for determination of trace amounts of platinum. Studies were performed on ionic chromatographic methods, in particular on electrochemical detection. In-depth research was done into platinum species analysis for the example of grass samples that were either uncontaminated or contaminated with platinum. Platinum levels were determined in various biotic and ecologically relevant materials (uncontaminated and contaminated), especially in body fluids, air-borne particles, soils, fuels, water. (orig.) [Deutsch] Verschiedene Aufschlussmethoden zur Bestimmung von Platin (adsorptive Voltammetrie, Graphitofen-Atomabsorptionsspektrometrie nach Abtrennung und Anreicherung, Ionenchromatographie) in biotischen und umweltrelevanten Materialien wurden getestet. Als geeignet erwies sich fuer die meisten Probenarten der Hochdruckaufschluss in Quarzgefaessen (max. 320 C und 130 bar), waehrend der offene Aufschluss nur fuer einfache Materialien und kleine Probenmengen zu empfehlen ist. Radiochemische Tracer-Methoden wurde zur Ueberpruefung von Aufschlussmethoden und Trenn- und Anreicherungsmethoden zur Bestimmung von Platin im Spurenbereich durchgefuehrt. Untersuchungen zur ionenchromatographischen Bestimmung, insbesondere zur elektrochemischen Detektion, wurden durchgefuehrt. Am Beispiel von unbelasteten und mit Platin belasteten Grasproben wurden eingehende Arbeiten zur Platin-Spezies-Analytik vorgenommen. Die Platin-Gehalte verschiedener biotischer und umweltrelevanter Materialien (unbelastet und belastet) wurden ermittelt, insbesondere in Koerperfluessigkeiten, Luftstaeuben, Boeden, Kraftstoffen, Wasserproben. (orig.)}
place = {Germany}
year = {1993}
month = {Dec}
}