Abstract
For the central plane of an assumed malignant tumor of the bladder, Cobalt - 60 treatment plans were calculated from published isodose curves. The calculation was done for the three field technique, unbalanced and balanced, and for 120 degree rotational therapy with wedge filter. A Rando-Alderson phantom and calibrated encapsulated {sup 7} LiF dosimeters with a standard deviation better than 3% of each were used to verify the treatment plans. Furthermore the dose distribution to an assumed extension of the tumor and to the rectum were measured. (author).
Citation Formats
Araujo, A M.C. de.
Comparison between the distribution of the calculated dose and the media with thermoluminescent dosemeters {sup 7} LiF in bladder tumor; Intercomparacao entre a distribuicao de dose calculada e a medida com dosimetros termoluminescentes de {sup 7} LiF em tumor de Bexiga.
Brazil: N. p.,
1974.
Web.
Araujo, A M.C. de.
Comparison between the distribution of the calculated dose and the media with thermoluminescent dosemeters {sup 7} LiF in bladder tumor; Intercomparacao entre a distribuicao de dose calculada e a medida com dosimetros termoluminescentes de {sup 7} LiF em tumor de Bexiga.
Brazil.
Araujo, A M.C. de.
1974.
"Comparison between the distribution of the calculated dose and the media with thermoluminescent dosemeters {sup 7} LiF in bladder tumor; Intercomparacao entre a distribuicao de dose calculada e a medida com dosimetros termoluminescentes de {sup 7} LiF em tumor de Bexiga."
Brazil.
@misc{etde_10108513,
title = {Comparison between the distribution of the calculated dose and the media with thermoluminescent dosemeters {sup 7} LiF in bladder tumor; Intercomparacao entre a distribuicao de dose calculada e a medida com dosimetros termoluminescentes de {sup 7} LiF em tumor de Bexiga}
author = {Araujo, A M.C. de}
abstractNote = {For the central plane of an assumed malignant tumor of the bladder, Cobalt - 60 treatment plans were calculated from published isodose curves. The calculation was done for the three field technique, unbalanced and balanced, and for 120 degree rotational therapy with wedge filter. A Rando-Alderson phantom and calibrated encapsulated {sup 7} LiF dosimeters with a standard deviation better than 3% of each were used to verify the treatment plans. Furthermore the dose distribution to an assumed extension of the tumor and to the rectum were measured. (author).}
place = {Brazil}
year = {1974}
month = {Dec}
}
title = {Comparison between the distribution of the calculated dose and the media with thermoluminescent dosemeters {sup 7} LiF in bladder tumor; Intercomparacao entre a distribuicao de dose calculada e a medida com dosimetros termoluminescentes de {sup 7} LiF em tumor de Bexiga}
author = {Araujo, A M.C. de}
abstractNote = {For the central plane of an assumed malignant tumor of the bladder, Cobalt - 60 treatment plans were calculated from published isodose curves. The calculation was done for the three field technique, unbalanced and balanced, and for 120 degree rotational therapy with wedge filter. A Rando-Alderson phantom and calibrated encapsulated {sup 7} LiF dosimeters with a standard deviation better than 3% of each were used to verify the treatment plans. Furthermore the dose distribution to an assumed extension of the tumor and to the rectum were measured. (author).}
place = {Brazil}
year = {1974}
month = {Dec}
}