Abstract
A nuclear magnetic resonance magnetometer with automatic signal search and field tracking is described. The magnetometer serves for measurements of the plane gap magnet fields, as well as the solenoid fields. The range of the measured fields is 0.06-6 T. The proton resonance is used throughout the whole field range. The permissible inhomogeneity of the measured field is 0.5% cm{sup -1}, the measurement error being 0.01%. The probe is connected with the rest part of the magnetometer and frequency meter by cables up to several tens of meters long, which allows to distant fiel measurements. 4 refs.; 1 fig.; 1 tab.
Citation Formats
Ivashkevich, S A, and Lagish, J.
Automatic proton resonance magnetometer up to 6 T; Avtomaticheskij yadernyj magnitometr s rezonansom na protonakh do 6 Tl.
USSR: N. p.,
1990.
Web.
Ivashkevich, S A, & Lagish, J.
Automatic proton resonance magnetometer up to 6 T; Avtomaticheskij yadernyj magnitometr s rezonansom na protonakh do 6 Tl.
USSR.
Ivashkevich, S A, and Lagish, J.
1990.
"Automatic proton resonance magnetometer up to 6 T; Avtomaticheskij yadernyj magnitometr s rezonansom na protonakh do 6 Tl."
USSR.
@misc{etde_10106317,
title = {Automatic proton resonance magnetometer up to 6 T; Avtomaticheskij yadernyj magnitometr s rezonansom na protonakh do 6 Tl}
author = {Ivashkevich, S A, and Lagish, J}
abstractNote = {A nuclear magnetic resonance magnetometer with automatic signal search and field tracking is described. The magnetometer serves for measurements of the plane gap magnet fields, as well as the solenoid fields. The range of the measured fields is 0.06-6 T. The proton resonance is used throughout the whole field range. The permissible inhomogeneity of the measured field is 0.5% cm{sup -1}, the measurement error being 0.01%. The probe is connected with the rest part of the magnetometer and frequency meter by cables up to several tens of meters long, which allows to distant fiel measurements. 4 refs.; 1 fig.; 1 tab.}
place = {USSR}
year = {1990}
month = {Dec}
}
title = {Automatic proton resonance magnetometer up to 6 T; Avtomaticheskij yadernyj magnitometr s rezonansom na protonakh do 6 Tl}
author = {Ivashkevich, S A, and Lagish, J}
abstractNote = {A nuclear magnetic resonance magnetometer with automatic signal search and field tracking is described. The magnetometer serves for measurements of the plane gap magnet fields, as well as the solenoid fields. The range of the measured fields is 0.06-6 T. The proton resonance is used throughout the whole field range. The permissible inhomogeneity of the measured field is 0.5% cm{sup -1}, the measurement error being 0.01%. The probe is connected with the rest part of the magnetometer and frequency meter by cables up to several tens of meters long, which allows to distant fiel measurements. 4 refs.; 1 fig.; 1 tab.}
place = {USSR}
year = {1990}
month = {Dec}
}