You need JavaScript to view this

Liquid scintillation counting standardization of ``125 I in organic and inorganic samples by the CIEMAT/NIST method; Calibracin por centelleo lquido del ``125 I en muestras orgnicas e inorgnicas, mediante el mtodo CIEMAT/NIST

Abstract

The liquid scintillation counting standardization of organic and inorganic samples of ``125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%.
Publication Date:
Dec 31, 1994
Product Type:
Technical Report
Report Number:
CIEMAT-743
Reference Number:
SCA: 440102; 400702; PA: SPN-94:0B0822; EDB-95:016697; SN: 95001297672
Resource Relation:
Other Information: PBD: [1994]
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEAR CHEMISTRY; SCINTILLATION COUNTING; IODINE 125; LIQUID SCINTILLATORS; ACETATES; CHOLESTEROL; ORGANIC COMPOUNDS; SODIUM IODIDES; STANDARDIZATION; 440102; 400702; RADIATION DOSEMETERS; PROPERTIES OF RADIOACTIVE MATERIALS
OSTI ID:
10104725
Research Organizations:
Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE95722437; TRN: ES94B0822
Availability:
OSTI; NTIS; INIS
Submitting Site:
INIS
Size:
30 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Rodriguez Barquera, L, Grau Malonda, A, Los Arcos Merino, J M, and Grau Carles, A. Liquid scintillation counting standardization of ``125 I in organic and inorganic samples by the CIEMAT/NIST method; Calibracin por centelleo lquido del ``125 I en muestras orgnicas e inorgnicas, mediante el mtodo CIEMAT/NIST. Spain: N. p., 1994. Web.
Rodriguez Barquera, L, Grau Malonda, A, Los Arcos Merino, J M, & Grau Carles, A. Liquid scintillation counting standardization of ``125 I in organic and inorganic samples by the CIEMAT/NIST method; Calibracin por centelleo lquido del ``125 I en muestras orgnicas e inorgnicas, mediante el mtodo CIEMAT/NIST. Spain.
Rodriguez Barquera, L, Grau Malonda, A, Los Arcos Merino, J M, and Grau Carles, A. 1994. "Liquid scintillation counting standardization of ``125 I in organic and inorganic samples by the CIEMAT/NIST method; Calibracin por centelleo lquido del ``125 I en muestras orgnicas e inorgnicas, mediante el mtodo CIEMAT/NIST." Spain.
@misc{etde_10104725,
title = {Liquid scintillation counting standardization of ``125 I in organic and inorganic samples by the CIEMAT/NIST method; Calibracin por centelleo lquido del ``125 I en muestras orgnicas e inorgnicas, mediante el mtodo CIEMAT/NIST}
author = {Rodriguez Barquera, L, Grau Malonda, A, Los Arcos Merino, J M, and Grau Carles, A}
abstractNote = {The liquid scintillation counting standardization of organic and inorganic samples of ``125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%.}
place = {Spain}
year = {1994}
month = {Dec}
}