Abstract
A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, The density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength bandwidth and energy profile and Rayleigh scattering in N{sub 2} was used for the optical system calibration. An absolute density of Cr atoms of n= 5x10``9 cm``-3 was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal US. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma.
Citation Formats
Tafalla, D, Cal, E de la, and Tabares, F L.
Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnostico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharge de neon.
Spain: N. p.,
1994.
Web.
Tafalla, D, Cal, E de la, & Tabares, F L.
Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnostico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharge de neon.
Spain.
Tafalla, D, Cal, E de la, and Tabares, F L.
1994.
"Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnostico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharge de neon."
Spain.
@misc{etde_10104711,
title = {Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnostico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharge de neon}
author = {Tafalla, D, Cal, E de la, and Tabares, F L}
abstractNote = {A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, The density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength bandwidth and energy profile and Rayleigh scattering in N{sub 2} was used for the optical system calibration. An absolute density of Cr atoms of n= 5x10``9 cm``-3 was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal US. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma.}
place = {Spain}
year = {1994}
month = {Dec}
}
title = {Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnostico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharge de neon}
author = {Tafalla, D, Cal, E de la, and Tabares, F L}
abstractNote = {A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, The density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength bandwidth and energy profile and Rayleigh scattering in N{sub 2} was used for the optical system calibration. An absolute density of Cr atoms of n= 5x10``9 cm``-3 was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal US. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma.}
place = {Spain}
year = {1994}
month = {Dec}
}