You need JavaScript to view this

Reliability assessment of PARR-1 renovated I and C system: linear channel

Abstract

This report is a part of effort and the reliability of PARR-1 instrumentation and control after renovation/upgradation and assessment of linear channel has been performed. Before renovation there was only one channel which is now replaced by two channels having the operation based on one out of two logic. In this assessment the technique of component count method (CCM) has been applied. The same technique has been used in the studies for other channels of renovated I and C system. The comparison one to one basis with the old system concludes that system unreliability has been decreased. (A.B.). 6 fig.
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
DNSRP-10(7)/90-2; PR-2/90.
Reference Number:
SCA: 220400; 220600; PA: AIX-23:008573; SN: 92000619684
Resource Relation:
Other Information: DN: 6 fig.; PBD: 1991
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; PARR REACTOR; REACTOR CONTROL SYSTEMS; EXPERIMENTAL DATA; REACTOR CHANNELS; REACTOR INSTRUMENTATION; REACTOR MONITORING SYSTEMS; REACTOR SAFETY; RELIABILITY; RISK ASSESSMENT; 220400; 220600; CONTROL SYSTEMS; RESEARCH, TEST, TRAINING, PRODUCTION, IRRADIATION, MATERIALS TESTING REACTORS
OSTI ID:
10104290
Research Organizations:
Pakistan Atomic Energy Commission, Islamabad (Pakistan). Directorate of Nuclear Safety and Radiation Protection
Country of Origin:
Pakistan
Language:
English
Other Identifying Numbers:
Other: ON: DE92612869; TRN: PK9100071008573
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
32 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Qamar, M A, Khaliq, M, and Habib, M A. Reliability assessment of PARR-1 renovated I and C system: linear channel. Pakistan: N. p., 1991. Web.
Qamar, M A, Khaliq, M, & Habib, M A. Reliability assessment of PARR-1 renovated I and C system: linear channel. Pakistan.
Qamar, M A, Khaliq, M, and Habib, M A. 1991. "Reliability assessment of PARR-1 renovated I and C system: linear channel." Pakistan.
@misc{etde_10104290,
title = {Reliability assessment of PARR-1 renovated I and C system: linear channel}
author = {Qamar, M A, Khaliq, M, and Habib, M A}
abstractNote = {This report is a part of effort and the reliability of PARR-1 instrumentation and control after renovation/upgradation and assessment of linear channel has been performed. Before renovation there was only one channel which is now replaced by two channels having the operation based on one out of two logic. In this assessment the technique of component count method (CCM) has been applied. The same technique has been used in the studies for other channels of renovated I and C system. The comparison one to one basis with the old system concludes that system unreliability has been decreased. (A.B.). 6 fig.}
place = {Pakistan}
year = {1991}
month = {Dec}
}