Abstract
A TLD-intercomparison test between the three institutions were performed in 1990/1991. Each laboratory organized an irradiation of TL-dosemeters from the two other institutions, and consequently evaluated own dosemeters irradiated at the other laboratories. Apart from one single measurement, the results are all within 10% of each other. Due to the lack of internal consistence in the observed results, the differences may very well reflect errors caused by the TLD-readout and shipment procedure, rather than differences in the basic dosimetry standards. 4 tabs.
Woehni, T;
[1]
Wallstroem, E;
[2]
Erkin, V
[3]
- Statens Inst. for Straalehygiene, Oslo (Norway)
- Sahlgrenska Sjukhuset, Goeteborg (Sweden)
- Nauchno-Issledovatel`skij Inst. Radiatsionnoj Gigieny, Leningrad (USSR)
Citation Formats
Woehni, T, Wallstroem, E, and Erkin, V.
TLD-intercomparison test. Between National Institute of Radiation Hygiene (Norway), Department of Radiation Physics at the University of Goeteborg (Sweden), and Leningrad Scientific Research Institute of Radiation Hygiene (USSR).
Norway: N. p.,
1991.
Web.
Woehni, T, Wallstroem, E, & Erkin, V.
TLD-intercomparison test. Between National Institute of Radiation Hygiene (Norway), Department of Radiation Physics at the University of Goeteborg (Sweden), and Leningrad Scientific Research Institute of Radiation Hygiene (USSR).
Norway.
Woehni, T, Wallstroem, E, and Erkin, V.
1991.
"TLD-intercomparison test. Between National Institute of Radiation Hygiene (Norway), Department of Radiation Physics at the University of Goeteborg (Sweden), and Leningrad Scientific Research Institute of Radiation Hygiene (USSR)."
Norway.
@misc{etde_10104110,
title = {TLD-intercomparison test. Between National Institute of Radiation Hygiene (Norway), Department of Radiation Physics at the University of Goeteborg (Sweden), and Leningrad Scientific Research Institute of Radiation Hygiene (USSR)}
author = {Woehni, T, Wallstroem, E, and Erkin, V}
abstractNote = {A TLD-intercomparison test between the three institutions were performed in 1990/1991. Each laboratory organized an irradiation of TL-dosemeters from the two other institutions, and consequently evaluated own dosemeters irradiated at the other laboratories. Apart from one single measurement, the results are all within 10% of each other. Due to the lack of internal consistence in the observed results, the differences may very well reflect errors caused by the TLD-readout and shipment procedure, rather than differences in the basic dosimetry standards. 4 tabs.}
place = {Norway}
year = {1991}
month = {Dec}
}
title = {TLD-intercomparison test. Between National Institute of Radiation Hygiene (Norway), Department of Radiation Physics at the University of Goeteborg (Sweden), and Leningrad Scientific Research Institute of Radiation Hygiene (USSR)}
author = {Woehni, T, Wallstroem, E, and Erkin, V}
abstractNote = {A TLD-intercomparison test between the three institutions were performed in 1990/1991. Each laboratory organized an irradiation of TL-dosemeters from the two other institutions, and consequently evaluated own dosemeters irradiated at the other laboratories. Apart from one single measurement, the results are all within 10% of each other. Due to the lack of internal consistence in the observed results, the differences may very well reflect errors caused by the TLD-readout and shipment procedure, rather than differences in the basic dosimetry standards. 4 tabs.}
place = {Norway}
year = {1991}
month = {Dec}
}