You need JavaScript to view this

Field test of a wind-powered vapor compression plant for sea-water desalination. Final report; Praxiserprobung einer windkraftgetriebenen Dampfverdichtungsanlage zur Meerwasserentsalzung. Schlussbericht

Abstract

The wind-powered mechanical compression plant for sea-water desalination, constructed and tested on a test stand in Munich (ref.no. 032 84-86 B), was installed on the North Sea island Borkum and has been operated together with a wind power plant with rigid rotor blades (type TW 45 of Renk Tacke Ltd). The power production of the TW 45 has varied rapidly on a large scale: Variations of 1:4 within one minute hasn`t been unusual. It has been possible to adjust the power consumption of the vapour compression plant simultaneously to the power production of the TW 45 by variation of the speed of the high-pressure blower within the range of 3000 to 6000 rpm and by variation of the power consumption of the electric resistance heating at the bottom of the evaporator. Only at high wind velocities it hasn`t been possible to transfer completely the power of the TW 45 to the vapour compression plant, because the power production exceeds at high wind velocities the maximum permissible power consumption. (orig.) With 2 refs., 1 tab., 19 figs. [Deutsch] Die in Muenchen gebaute und am Pruefstand erprobte Dampfverdichtungsanlage zur Meerwasserentsalzung (FKZ 032 84 86 B) wurde auf der Insel Borkum installiert und  More>>
Publication Date:
Sep 01, 1990
Product Type:
Miscellaneous
Report Number:
ETDE-mf-2734762
Reference Number:
SCA: 170601; 320300; PA: DE-91:011268; SN: 91000607519
Resource Relation:
Other Information: PBD: Sep 1990
Subject:
17 WIND ENERGY; 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; DESALINATION PLANTS; DESIGN; OPERATION; WIND TURBINES; COMPRESSORS; TESTING; ROTORS; DIAGRAMS; MEASURING METHODS; 170601; 320300; APPLICATIONS; INDUSTRIAL AND AGRICULTURAL PROCESSES
OSTI ID:
10103770
Research Organizations:
Gesellschaft fuer Technische Studien, Entwicklung, Planung mbH (SEP), Muenchen (Germany); Bundesministerium fuer Forschung und Technologie, Bonn (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE92734762; CNN: Contract BMFT 0328486C; TRN: DE9111268
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
DE
Size:
58 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Coutelle, R, Gaiser, P, Kowalczyk, D, and Plantikow, U. Field test of a wind-powered vapor compression plant for sea-water desalination. Final report; Praxiserprobung einer windkraftgetriebenen Dampfverdichtungsanlage zur Meerwasserentsalzung. Schlussbericht. Germany: N. p., 1990. Web.
Coutelle, R, Gaiser, P, Kowalczyk, D, & Plantikow, U. Field test of a wind-powered vapor compression plant for sea-water desalination. Final report; Praxiserprobung einer windkraftgetriebenen Dampfverdichtungsanlage zur Meerwasserentsalzung. Schlussbericht. Germany.
Coutelle, R, Gaiser, P, Kowalczyk, D, and Plantikow, U. 1990. "Field test of a wind-powered vapor compression plant for sea-water desalination. Final report; Praxiserprobung einer windkraftgetriebenen Dampfverdichtungsanlage zur Meerwasserentsalzung. Schlussbericht." Germany.
@misc{etde_10103770,
title = {Field test of a wind-powered vapor compression plant for sea-water desalination. Final report; Praxiserprobung einer windkraftgetriebenen Dampfverdichtungsanlage zur Meerwasserentsalzung. Schlussbericht}
author = {Coutelle, R, Gaiser, P, Kowalczyk, D, and Plantikow, U}
abstractNote = {The wind-powered mechanical compression plant for sea-water desalination, constructed and tested on a test stand in Munich (ref.no. 032 84-86 B), was installed on the North Sea island Borkum and has been operated together with a wind power plant with rigid rotor blades (type TW 45 of Renk Tacke Ltd). The power production of the TW 45 has varied rapidly on a large scale: Variations of 1:4 within one minute hasn`t been unusual. It has been possible to adjust the power consumption of the vapour compression plant simultaneously to the power production of the TW 45 by variation of the speed of the high-pressure blower within the range of 3000 to 6000 rpm and by variation of the power consumption of the electric resistance heating at the bottom of the evaporator. Only at high wind velocities it hasn`t been possible to transfer completely the power of the TW 45 to the vapour compression plant, because the power production exceeds at high wind velocities the maximum permissible power consumption. (orig.) With 2 refs., 1 tab., 19 figs. [Deutsch] Die in Muenchen gebaute und am Pruefstand erprobte Dampfverdichtungsanlage zur Meerwasserentsalzung (FKZ 032 84 86 B) wurde auf der Insel Borkum installiert und zusammen mit einem Windenergiekonverter mit starren Rotorblaettern (Typ TW 45 der Firma Renk Tacke) zur Entsalzung von Meerwasser eingesetzt. Die Leistungsabgabe des Windenergiekonverters variierte sehr stark und sehr schnell: Leistungsschwankungen im Verhaeltnis 1:4 innerhalb einer Minute waren keine Seltenheit. Durch Variation der Drehzahl des Hochdruckgeblaeses im Bereich zwischen 3000 und 6000 Upm und durch Hinzu- und Abschalten von Heizstaeben im Verdampfer konnte die Leistungsabgabe des TW 45 von der Dampfverdichtungsanlage synchron aufgenommen werden. Nur bei hohen Windgeschwindigkeiten konnte die Leistung des TW 45 von der Dampfverdichtungsanlage nicht in vollem Umfang aufgenommen werden, da bei hohen Windgeschwindigkeiten die Leistung des TW 45 groesser war als die maximal zulaessige Leistungsaufnahme der Dampfverdichtungsanlage. (orig.) With 2 refs., 1 tab., 19 figs.}
place = {Germany}
year = {1990}