You need JavaScript to view this

The magnets for extraction from the KEK proton synchrotron main ring

Abstract

Fast extraction from the KEK proton synchrotron main ring started at December 1976 and ended at June 1981 with ending the experiments to use the KEK 1m Bubble Chamber. On the other hand, slow extraction from the KEK proton synchrotron main ring started at November 1977 and the first stage on the slow extraction ended at May 1990 with changing the flat-top duration from about 0.65 second to about 2 second. We made most magnets for extraction from the KEK proton synchrotron main ring, but we don`t report about these magnets until now. As we think that compiling the materials of the extraction`s magnets is useful, we publish this report. (author).
Publication Date:
Jul 01, 1994
Product Type:
Technical Report
Report Number:
KEK-94-4
Reference Number:
SCA: 430303; PA: JPN-94:011227; EDB-95:009467; SN: 95001296261
Resource Relation:
Other Information: PBD: Jul 1994
Subject:
43 PARTICLE ACCELERATORS; KICKER MAGNETS; KEK SYNCHROTRON; PROTON BEAMS; GEV RANGE 10-100; BEAM EXTRACTION; SEPTUM MAGNETS; MAGNET CORES; MAGNET COILS; SUPPORTS; 430303; EXPERIMENTAL FACILITIES AND EQUIPMENT
OSTI ID:
10102287
Research Organizations:
National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE95722069; TRN: JP9411227
Availability:
OSTI; NTIS; INIS
Submitting Site:
JPN
Size:
16 p.
Announcement Date:
Jun 30, 2005

Citation Formats

Sakamoto, Y, and Mitsunobu, S. The magnets for extraction from the KEK proton synchrotron main ring. Japan: N. p., 1994. Web.
Sakamoto, Y, & Mitsunobu, S. The magnets for extraction from the KEK proton synchrotron main ring. Japan.
Sakamoto, Y, and Mitsunobu, S. 1994. "The magnets for extraction from the KEK proton synchrotron main ring." Japan.
@misc{etde_10102287,
title = {The magnets for extraction from the KEK proton synchrotron main ring}
author = {Sakamoto, Y, and Mitsunobu, S}
abstractNote = {Fast extraction from the KEK proton synchrotron main ring started at December 1976 and ended at June 1981 with ending the experiments to use the KEK 1m Bubble Chamber. On the other hand, slow extraction from the KEK proton synchrotron main ring started at November 1977 and the first stage on the slow extraction ended at May 1990 with changing the flat-top duration from about 0.65 second to about 2 second. We made most magnets for extraction from the KEK proton synchrotron main ring, but we don`t report about these magnets until now. As we think that compiling the materials of the extraction`s magnets is useful, we publish this report. (author).}
place = {Japan}
year = {1994}
month = {Jul}
}