DOE Data Explorer title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data

Abstract

In these data sets, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented. An indication of the sample is in the file name and in the first line of data.

Authors:
Publication Date:
Other Number(s):
854
DOE Contract Number:  
FY13 AOP 5.1
Research Org.:
USDOE Geothermal Data Repository (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Geothermal Technologies Program (EE-2C)
Subject:
15 Geothermal Energy
Keywords:
geothermal; experimental; fracture; mechanics; geochemistry; Pressure; Temperature; differential pressure; aperture; Desert Peak; Titanium; granite; pressure gradient; fracture investigation
Geolocation:
37.888077102603, -122.21672058105
OSTI Identifier:
1422727
DOI:
https://doi.org/10.15121/1422727
Project Location:


Citation Formats

Kneafsey, Tim. Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data. United States: N. p., 2016. Web. doi:10.15121/1422727.
Kneafsey, Tim. Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data. United States. doi:https://doi.org/10.15121/1422727
Kneafsey, Tim. 2016. "Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data". United States. doi:https://doi.org/10.15121/1422727. https://www.osti.gov/servlets/purl/1422727. Pub date:Fri Sep 30 00:00:00 EDT 2016
@article{osti_1422727,
title = {Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data},
author = {Kneafsey, Tim},
abstractNote = {In these data sets, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented. An indication of the sample is in the file name and in the first line of data.},
doi = {10.15121/1422727},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Sep 30 00:00:00 EDT 2016},
month = {Fri Sep 30 00:00:00 EDT 2016}
}