skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Dimensions and Measurements of Debuncher Band 3 and 4 Waveguide-Coax Launchers

Technical Report ·
DOI:https://doi.org/10.2172/984593· OSTI ID:984593

This note is a document about dimensions and measurement results of waveguide-coax launchers (Band 3 and 4) installed on the arrays in debuncher cooling upgrade. Shown in Figure 1 and 5 are schematic drawings of launchers (pick-up) in the cross section along the longitudinal direction (beam direction) of the arrays. The unit in these drawings is inch. Note: although there are upper band and lower band for pickup arrays, the launchers are the same to avoid possible confusion during installation. Launchers for band 3 and 4 kickers were made by Penn-engineering Inc., therefor no schematic drawings are presented in this note. RF Measurements were made on all launchers (port) and printed in hard copies for future reference. Since the measurement results are similar to each other, only a few plots for each type of launcher/band are presented in this document. There are two types of measured S11 parameters. One is the measurement made at the end of design/tuning stage using a launcher and a straight section of band 3 or 4 waveguide terminated with a cone of absorber. I use 'Original' to denote this kind of measurement. As shown in Figure 2, 6, 9 and 12, the original S11 of all launchers are below or around -20 db over the full band 3 or 4. The other type of measurement is the one made after these launchers were installed onto the array including several type N feedthrough or connectors, elbows, waveguide bends (kicker) and magic Ts (kicker) etc. The kicker arrays were terminated with wedges of absorber. During all measurements (pickup array or kicker array) when one launcher was being measured, all other launchers were terminated with 50 ohm terminator. As shown in Figure 3, 4, 7, 8, 10, 11, 13 and 14 these 'final' S11s are around -15 db.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
984593
Report Number(s):
FERMILAB-PBAR-NOTE-641; oai:inspirehep.net:863803; TRN: US1006006
Country of Publication:
United States
Language:
English

Similar Records

Dimensions and Measurements of Debuncher Band 1 and 2 Waveguide-Coax Launchers (Final Version)
Technical Report · Tue Feb 15 00:00:00 EST 2000 · OSTI ID:984593

Dimensions and Measurements of Waveguide-Coax Launchers for Pbar Accumulator Core Cooling Upgrade
Technical Report · Mon Jul 15 00:00:00 EDT 2002 · OSTI ID:984593

Dimensions and Measurements of Waveguide-Coax Adapters (Part I)
Technical Report · Mon Apr 19 00:00:00 EDT 1999 · OSTI ID:984593