skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Minimizing Glovebox Glove Breaches: PART II.

Conference ·
OSTI ID:977947

As a matter of good business practices, a team of glovebox experts from Los Alamos National Laboratory (LANL) has been assembled to proactively investigate processes and procedures that minimize unplanned breaches in the glovebox, e.g., glove failures. A major part of this effort involves the review of glovebox glove failures that have occurred at the Plutonium Facility and at the Chemical and Metallurgy Research Facility. Information dating back to 1993 has been compiled from formal records. This data has been combined with information obtained from a baseline inventory of about 9,000 glovebox gloves. The key attributes tracked include those related to location, the glovebox glove, type and location of breaches, the worker, and the consequences resulting from breaches. This glovebox glove failure analysis yielded results in the areas of the ease of collecting this type of data, the causes of most glove failures that have occurred, the effectiveness of current controls, and recommendations to improve hazard control systems. As expected, a significant number of breaches involve high-risk operations such as grinding, hammering, using sharps (especially screwdrivers), and assembling equipment. Surprisingly, tasks such as the movement of equipment and material between gloveboxes and the opening of cans are also major contributions of breaches. Almost half the gloves fail within a year of their install date. The greatest consequence for over 90% of glovebox glove failures is alpha contamination of protective clothing. Personnel self-monitoring at the gloveboxes continues to be the most effective way of detecting glovebox glove failures. Glove failures from these tasks can be reduced through changes in procedures and the design of remote-handling apparatus. The Nuclear Materials Technology Division management uses this information to improve hazard control systems to reduce the number of unplanned breaches in the glovebox further. As a result, excursions of contaminants into the operator's breathing zone and excess exposure to the radiological sources associated with unplanned breaches in the glovebox have been minimized. In conclusion, investigations of control failures, near misses, and accidents contribute to an organization's scientific and technological excellence by providing information that can be used to increase its operational safety.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE
OSTI ID:
977947
Report Number(s):
LA-UR-05-0651; TRN: US201012%%831
Resource Relation:
Conference: Submitted to: WM’05 Conference, February 27 - March 3, 2005, Tucson, AZ
Country of Publication:
United States
Language:
English