Enhanced Algorithm for Traceability Measurements in UF6 Flow Pipe
Abstract
The Blend Down Monitoring System (BDMS) is used to continually assess the mixing and downblending of highly enriched uranium (HEU) with low-enriched uranium (LEU). This is accomplished by measuring the enrichment and the fissile mass flow rate of the UF{sub 6} gas located in each process pipe of the system by inducing the fission of the {sup 235}U contained in the gas. Measurements are taken along this process route to trace the HEU content all the way to the product stream, ensuring that HEU was down blended. A problem associated with the current traceability measuring algorithm is that it does not account for the time-varying background that is introduced to the system by the movement of the shutter located at the HEU leg of the process. The current way of dealing with that problem is to discard the data for periods when the HEU shutter is open (50% of overall data) because it correlates with the same timeframe in which the direct contribution to background from the HEU shutter was seen. The advanced algorithm presented in this paper allows for continuous measurement of traceability (100%) by accurately accounting for the varying background during the shutter-movement cycle. This algorithm utilizes advancedmore »
- Authors:
- ORNL
- Publication Date:
- Research Org.:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
- Sponsoring Org.:
- USDOE National Nuclear Security Administration (NNSA)
- OSTI Identifier:
- 963904
- DOE Contract Number:
- DE-AC05-00OR22725
- Resource Type:
- Conference
- Resource Relation:
- Conference: INMM 48th Annual Meeting, Tucson, AZ, USA, 20070708, 20070712
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; URANIUM HEXAFLUORIDE; FLOW RATE; HIGHLY ENRICHED URANIUM; SLIGHTLY ENRICHED URANIUM; MIXING; ALGORITHMS; BACKGROUND RADIATION; ON-LINE MEASUREMENT SYSTEMS; PERFORMANCE
Citation Formats
Copinger, Thomas E, March-Leuba, Jose A, and Upadhyaya, Belle R. Enhanced Algorithm for Traceability Measurements in UF6 Flow Pipe. United States: N. p., 2007.
Web.
Copinger, Thomas E, March-Leuba, Jose A, & Upadhyaya, Belle R. Enhanced Algorithm for Traceability Measurements in UF6 Flow Pipe. United States.
Copinger, Thomas E, March-Leuba, Jose A, and Upadhyaya, Belle R. Mon .
"Enhanced Algorithm for Traceability Measurements in UF6 Flow Pipe". United States.
doi:.
@article{osti_963904,
title = {Enhanced Algorithm for Traceability Measurements in UF6 Flow Pipe},
author = {Copinger, Thomas E and March-Leuba, Jose A and Upadhyaya, Belle R},
abstractNote = {The Blend Down Monitoring System (BDMS) is used to continually assess the mixing and downblending of highly enriched uranium (HEU) with low-enriched uranium (LEU). This is accomplished by measuring the enrichment and the fissile mass flow rate of the UF{sub 6} gas located in each process pipe of the system by inducing the fission of the {sup 235}U contained in the gas. Measurements are taken along this process route to trace the HEU content all the way to the product stream, ensuring that HEU was down blended. A problem associated with the current traceability measuring algorithm is that it does not account for the time-varying background that is introduced to the system by the movement of the shutter located at the HEU leg of the process. The current way of dealing with that problem is to discard the data for periods when the HEU shutter is open (50% of overall data) because it correlates with the same timeframe in which the direct contribution to background from the HEU shutter was seen. The advanced algorithm presented in this paper allows for continuous measurement of traceability (100%) by accurately accounting for the varying background during the shutter-movement cycle. This algorithm utilizes advanced processing techniques that identify and discriminate the different sources of background radiation, instead of grouping them into one background group for the whole measurement cycle. By using this additional information, the traceability measurement statistics can achieve a greater number of values, thus improving the overall usefulness of these measurements in the BDMS. The effectiveness of the new algorithm was determined by modeling it in a simulation and ensuring that it retained its integrity through a large number of runs, including various shutter-failure conditions. Each run was performed with varying amounts of background radiation from each individual source and with varying traceability counts. The simulations documented in this paper prove that the algorithm can stand up to various transients introduced into the system, such as failure of shutter movement.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jan 01 00:00:00 EST 2007},
month = {Mon Jan 01 00:00:00 EST 2007}
}
-
ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing an automated UF6 cylinder verification station concept based on the combined collection of traditional enrichment-meter (186 keV photons from U-235) data and non-traditional, neutron-induced, high-energy gamma-signatures (3-8.5 MeV) with an array of collimated, medium-resolution scintillators. Previous (2010) work at PNNL demonstrated proof-of-principle that this hybrid method yields accurate, full-volume assay of the cylinder enrichment, reduces systematic errors when compared to several other enrichment assay methods, and provides simplified instrumentation and algorithms suitable for long-term unattended operations. We used Monte Carlo modeling with MCNP5 to support system design (e.g., number and configuration ofmore »
-
Traceability of radiation measurements: musings of a user
Although users of radiation desire measurement traceability for a number of reasons, including legal, regulatory, contractual, and quality assurance requirements, there exists no real definition of the term in the technical literature. Definitions are proposed for both traceability and traceability to the National Bureau of Standards. The hierarchy of radiation standards is discussed and allowable uncertainties are given for each level. Areas of need with respect to radiation standards are identified, and a system of secondary radiation calibration laboratories is proposed as a means of providing quality calibrations and traceability on a routine basis. -
Pipe flow measurements of a transparent non-Newtonian slurry. [Includes velocity profiles]
An experimental description of the flow structure of non-Newtonian slurries in the laminar, transitional, and full turbulent pipe flow regimes is the primary objective of this research. Experiments were conducted in a large-scale pipe slurry flow facility with an inside pipe diameter of 51 mm. The transparent slurry formulated for these experiments exhibited a yield-power-law behavior from cup viscometer measurements. The velocity profile for laminar flow from laser Doppler velocimeter (LDV) measurements had a central plug flow region, and it was in agreement with theory. The range of the transition region was narrower than that for a Newtonian fluid. Themore » -
An Energy Signature Scheme for Steam Trap Assessment and Flow Rate Estimation Using Pipe-Induced Acoustic Measurements
The US Congress has passed legislation dictating that all government agencies establish a plan and process for improving energy efficiencies at their sites. In response to this legislation, Oak Ridge National Laboratory (ORNL) has recently conducted a pilot study to explore the deployment of a wireless sensor system for a real-time measurement-based energy efficiency optimization framework within the steam distribution system within the ORNL campus. We make assessments on the real-time status of the distribution system by observing the state measurements of acoustic sensors mounted on the steam pipes/traps/valves. In this paper, we describe a spectral-based energy signature scheme thatmore »