Title: Cleanup Verification Package for the 116-K-2 Effluent Trench

Abstract

This cleanup verification package documents completion of remedial action for the 116-K-2 effluent trench, also referred to as the 116-K-2 mile-long trench and the 116-K-2 site. During its period of operation, the 116-K-2 site was used to dispose of cooling water effluent from the 105-KE and 105-KW Reactors by percolation into the soil. This site also received mixed liquid wastes from the 105-KW and 105-KE fuel storage basins, reactor floor drains, and miscellaneous decontamination activities.

Authors:
Publication Date:
Research Org.:
Washington Closure Hanford
Sponsoring Org.:
USDOE
OSTI Identifier:
945303
Report Number(s):
CVP-2006-00001, Rev. 0
TRN: US0901199
DOE Contract Number:  
DE-AC06-05RL14655
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 54 ENVIRONMENTAL SCIENCES; DECONTAMINATION; LIQUID WASTES; REMEDIAL ACTION; STORAGE; VERIFICATION; WATER; Hanford, 100K Area; 116-K-2 effluent trench; 116-K-2 mile-long trench; 116-K-2 site; 105-KE Reactor; 105-KW Reactor; fuel storage basin, reactor floor drain

Citation Formats

J. M. Capron. Cleanup Verification Package for the 116-K-2 Effluent Trench. United States: N. p., 2006. Web. doi:10.2172/945303.
J. M. Capron. Cleanup Verification Package for the 116-K-2 Effluent Trench. United States. doi:10.2172/945303.
J. M. Capron. Tue . "Cleanup Verification Package for the 116-K-2 Effluent Trench". United States. doi:10.2172/945303. https://www.osti.gov/servlets/purl/945303.
@article{osti_945303,
title = {Cleanup Verification Package for the 116-K-2 Effluent Trench},
author = {J. M. Capron},
abstractNote = {This cleanup verification package documents completion of remedial action for the 116-K-2 effluent trench, also referred to as the 116-K-2 mile-long trench and the 116-K-2 site. During its period of operation, the 116-K-2 site was used to dispose of cooling water effluent from the 105-KE and 105-KW Reactors by percolation into the soil. This site also received mixed liquid wastes from the 105-KW and 105-KE fuel storage basins, reactor floor drains, and miscellaneous decontamination activities.},
doi = {10.2172/945303},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2006},
month = {4}
}