skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

Abstract

The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

Authors:
; ; ; ; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
944334
Report Number(s):
LLNL-JRNL-400003
Journal ID: ISSN 0034-6748; RSINAK; TRN: US0900565
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments, vol. 79, n/a, March 10, 2008, pp. 33301; Journal Volume: 79
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION; 42 ENGINEERING; CALIBRATION; ELECTRON SOURCES; ELECTRON SPECTROMETERS; ELECTRONS; ENERGY RANGE; LASERS; LUMINESCENCE; PHOTONS; PLATES; RADIATION TRANSPORT; SPECTROMETERS; TARGETS

Citation Formats

Chen, H, Back, N L, Eder, D C, Ping, Y, Song, P M, and Throop, A. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV. United States: N. p., 2007. Web.
Chen, H, Back, N L, Eder, D C, Ping, Y, Song, P M, & Throop, A. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV. United States.
Chen, H, Back, N L, Eder, D C, Ping, Y, Song, P M, and Throop, A. Mon . "Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV". United States. https://www.osti.gov/servlets/purl/944334.
@article{osti_944334,
title = {Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV},
author = {Chen, H and Back, N L and Eder, D C and Ping, Y and Song, P M and Throop, A},
abstractNote = {The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.},
doi = {},
journal = {Review of Scientific Instruments, vol. 79, n/a, March 10, 2008, pp. 33301},
number = ,
volume = 79,
place = {United States},
year = {Mon Dec 10 00:00:00 EST 2007},
month = {Mon Dec 10 00:00:00 EST 2007}
}