Title: ESTIMATING THE STRENGTH OF SINGLE-ENDED DISLOCATION SOURCES IN MICROMETER-SIZED SINGLE CRYSTALS

Abstract

A recent study indicated that the behavior of single-ended dislocation sources contributes to the flow strength of micrometer-scale crystals. In this study 3D discrete dislocation dynamics simulations of micrometer-sized volumes are used to calculate the effects of anisotropy of dislocation line tension (increasing Poisson's ratio, {nu}) on the strength of single-ended dislocation sources and, to compare them with the strength of double-ended sources of equal length. This is done by directly modeling their plastic response within a 1 micron cubed FCC Ni single crystal using DDS. In general, double-ended sources are stronger than single-ended sources of an equal length and exhibit no significant effects from truncating the long-range elastic fields at this scale. The double-ended source strength increases with Poisson ratio ({nu}), exhibiting an increase of about 50% at u = 0.38 (value for Ni) as compared to the value at {nu} = 0. Independent of dislocation line direction, for {nu} greater than 0.20, the strengths of single-ended sources depend upon the sense of the stress applied. The value for {alpha}, in the expression for strength, {tau} = {alpha}(L){micro}b/L is shown to vary from 0.4 to 0.84 depending upon the character of the dislocation and the direction of operation ofmore » the source at {nu} corresponding to that of Ni, 0.38 and a length of 933b. By varying the lengths of the sources from 933b to 233b, it was shown that the scaling of the strength of single-ended and double-ended sources with their length both follow a ln(L/b)/(L/b) dependence. Surface image stresses are shown to have little effect on the critical stress of single-ended sources at a length of {approx}250b or greater. The relationship between these findings and a recent statistical model for the hardening of small volumes is also discussed.« less

Authors:
; ; ; ; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
942032
Report Number(s):
UCRL-JRNL-230783
TRN: US200825%%726
DOE Contract Number:
W-7405-ENG-48
Resource Type:
Journal Article
Resource Relation:
Journal Name: Philosophical Magazine , vol. 87, no. 30, January 10, 2007, pp. 4777-4794; Journal Volume: 87; Journal Issue: 30
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; ANISOTROPY; DISLOCATIONS; HARDENING; MONOCRYSTALS; PLASTICS; POISSON RATIO; SIMULATION; STATISTICAL MODELS; STRESSES

Citation Formats

Rao, S I, Dimiduk, D M, Tang, M, Parthasarathy, T A, Uchic, M D, and Woodward, C. ESTIMATING THE STRENGTH OF SINGLE-ENDED DISLOCATION SOURCES IN MICROMETER-SIZED SINGLE CRYSTALS. United States: N. p., 2007. Web.
Rao, S I, Dimiduk, D M, Tang, M, Parthasarathy, T A, Uchic, M D, & Woodward, C. ESTIMATING THE STRENGTH OF SINGLE-ENDED DISLOCATION SOURCES IN MICROMETER-SIZED SINGLE CRYSTALS. United States.
Rao, S I, Dimiduk, D M, Tang, M, Parthasarathy, T A, Uchic, M D, and Woodward, C. Thu . "ESTIMATING THE STRENGTH OF SINGLE-ENDED DISLOCATION SOURCES IN MICROMETER-SIZED SINGLE CRYSTALS". United States. doi:. https://www.osti.gov/servlets/purl/942032.
@article{osti_942032,
title = {ESTIMATING THE STRENGTH OF SINGLE-ENDED DISLOCATION SOURCES IN MICROMETER-SIZED SINGLE CRYSTALS},
author = {Rao, S I and Dimiduk, D M and Tang, M and Parthasarathy, T A and Uchic, M D and Woodward, C},
abstractNote = {A recent study indicated that the behavior of single-ended dislocation sources contributes to the flow strength of micrometer-scale crystals. In this study 3D discrete dislocation dynamics simulations of micrometer-sized volumes are used to calculate the effects of anisotropy of dislocation line tension (increasing Poisson's ratio, {nu}) on the strength of single-ended dislocation sources and, to compare them with the strength of double-ended sources of equal length. This is done by directly modeling their plastic response within a 1 micron cubed FCC Ni single crystal using DDS. In general, double-ended sources are stronger than single-ended sources of an equal length and exhibit no significant effects from truncating the long-range elastic fields at this scale. The double-ended source strength increases with Poisson ratio ({nu}), exhibiting an increase of about 50% at u = 0.38 (value for Ni) as compared to the value at {nu} = 0. Independent of dislocation line direction, for {nu} greater than 0.20, the strengths of single-ended sources depend upon the sense of the stress applied. The value for {alpha}, in the expression for strength, {tau} = {alpha}(L){micro}b/L is shown to vary from 0.4 to 0.84 depending upon the character of the dislocation and the direction of operation of the source at {nu} corresponding to that of Ni, 0.38 and a length of 933b. By varying the lengths of the sources from 933b to 233b, it was shown that the scaling of the strength of single-ended and double-ended sources with their length both follow a ln(L/b)/(L/b) dependence. Surface image stresses are shown to have little effect on the critical stress of single-ended sources at a length of {approx}250b or greater. The relationship between these findings and a recent statistical model for the hardening of small volumes is also discussed.},
doi = {},
journal = {Philosophical Magazine , vol. 87, no. 30, January 10, 2007, pp. 4777-4794},
number = 30,
volume = 87,
place = {United States},
year = {Thu May 03 00:00:00 EDT 2007},
month = {Thu May 03 00:00:00 EDT 2007}
}
  • Analysis of poly(ethylene glycol)(PEG)-containing particles by online single particle aerosol mass spectrometers equipped with laser desorption ionization (LDI) is reported. We demonstrate that PEG-containing particles are useful in the development of aerosol mass spectrometers because of their ease of preparation, low cost, and inherently recognizable mass spectra. Solutions containing millimolar quantities of PEGs were nebulized and, after drying, the resultant micrometer-sized PEG containing particles were sampled. LDI (266 nm) of particles containing NaCl and PEG molecules of average molecular weight <500 generated mass spectra reminiscent of mass spectra of PEG collected by other MS schemes including the characteristic distribution ofmore » positive ions (Na{sup +} adducts) separated by the 44 Da of the ethylene oxide units separating each degree of polymerization. PEGs of average molecular weight >500 were detected from particles that also contained t the tripeptide tyrosine-tyrosine-tyrosine or 2,5-dihydroxybenzoic acid, which were added to nebulized solutions to act as matrices to assist LDI using pulsed 266 nm and 355 nm lasers, respectively. Experiments were performed on two aerosol mass spectrometers, one reflectron and one linear, that each utilize two time-of-flight mass analyzers to detect positive and negative ions created from a single particle. PEG-containing particles are currently being employed in the optimization of our bioaerosol mass spectrometers for the application of measurements of complex biological samples, including human effluents, and we recommend that the same strategies will be of great utility to the development of any online aerosol LDI mass spectrometer platform.« less
  • The plastic deformation of submicron-size copper single crystals in the form of pillars has been characterized during in-situ compression in the transmission electron microscope up to strains of 28-33% using a state-of-the-art holder (PI-95 PicoIndenter). The dimensions of the crystals used were approx. 500 Multiplication-Sign 250 Multiplication-Sign 200 nm{sup 3} with the compression axis oriented 1.6 Degree-Sign from [110]. Local crystallographic orientations have been determined with high accuracy using a Kikuchi diffraction method and glide of dislocations over a pillar has also been observed directly by dark field imaging. The variation in the local orientation during deformation has been followedmore » by in-situ convergent beam electron Kikuchi diffraction. The in-situ observations have been followed up by post-deformation measurements with the samples still mounted in the electron microscope. Crystal breakup following localized deformation was observed in two of three crystals examined, and for all crystals the direction of rotation during deformation is in agreement with slip taking place on a subset of the four slip systems, with the highest Schmid factors on the (111) and (- 1-11) slip planes. A diffraction-based Burgers vector analysis confirms that the active dislocations are from slip systems with the highest Schmid factors. These results from testing of micropillars are in good agreement with the deformation behaviour previously reported for both single- and poly-crystal samples with dimensions in the millimetre range. - Highlights: Black-Right-Pointing-Pointer We performed in-situ plastic deformation of submicron-sized copper single crystals. Black-Right-Pointing-Pointer We measured in-situ and ex-situ crystal rotation and imaged dislocation activities. Black-Right-Pointing-Pointer We measured crystallographic orientations and analyzed dislocation Burgers vectors. Black-Right-Pointing-Pointer Crystals' rotation in agreement with slip of dislocations with highest Schmid factor. Black-Right-Pointing-Pointer These results in good agreement with millimeter-scale samples' deformation behavior.« less