skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Engineering Specification Document (ESD) of X-ray Vacuum Transport System (XVTS) for LCLS XTOD

Abstract

The vacuum system of the X-Ray Vacuum Transport System (XVTS) for the Linac Coherent Light Source (LCLS) X-ray Transport, Optics and Diagnostics (XTOD) system has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The preliminary system layout, detailed analyses and suggested selection of the vacuum components for the XTOD tunnel section are presented in the preliminary design report [1]. This document briefly reviews the preliminary design and provides engineering specifications for the system, which can be used as 'design to' specifications for the final design. Also included are the requirements of plans for procurement, mechanical integration, schedule and the cost estimates.

Authors:
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
928202
Report Number(s):
UCRL-TR-218772
TRN: US0804203
DOE Contract Number:
W-7405-ENG-48
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; DESIGN; LIGHT SOURCES; LINEAR ACCELERATORS; OPTICS; PROCUREMENT; SAFETY REPORTS; SCHEDULES; SPECIFICATIONS; TRANSPORT; VACUUM SYSTEMS

Citation Formats

Shen, S. Engineering Specification Document (ESD) of X-ray Vacuum Transport System (XVTS) for LCLS XTOD. United States: N. p., 2006. Web. doi:10.2172/928202.
Shen, S. Engineering Specification Document (ESD) of X-ray Vacuum Transport System (XVTS) for LCLS XTOD. United States. doi:10.2172/928202.
Shen, S. Wed . "Engineering Specification Document (ESD) of X-ray Vacuum Transport System (XVTS) for LCLS XTOD". United States. doi:10.2172/928202. https://www.osti.gov/servlets/purl/928202.
@article{osti_928202,
title = {Engineering Specification Document (ESD) of X-ray Vacuum Transport System (XVTS) for LCLS XTOD},
author = {Shen, S},
abstractNote = {The vacuum system of the X-Ray Vacuum Transport System (XVTS) for the Linac Coherent Light Source (LCLS) X-ray Transport, Optics and Diagnostics (XTOD) system has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The preliminary system layout, detailed analyses and suggested selection of the vacuum components for the XTOD tunnel section are presented in the preliminary design report [1]. This document briefly reviews the preliminary design and provides engineering specifications for the system, which can be used as 'design to' specifications for the final design. Also included are the requirements of plans for procurement, mechanical integration, schedule and the cost estimates.},
doi = {10.2172/928202},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jan 25 00:00:00 EST 2006},
month = {Wed Jan 25 00:00:00 EST 2006}
}

Technical Report:

Save / Share:
  • The design of the X-Ray Vacuum Transport System (XVTS) for the Linac Coherent Light Source (LCLS) X-ray Transport, Optics and Diagnostics (XTOD) system has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. A preliminary design review was held on 11/14/05 [1][2]. This FDR (Final Design Report) presents system configuration, detailed analyses and selection of the mechanical and electrical components for the XTOD tunnel section, as well as the response to all issues raised in the review committee report. Also included are the plans for procurement, mechanical integration,more » schedule and the cost estimates. It should be noticed that, after the XVTS PDR, LCLS management has decided to lower the number of beamlines from three to one, and shorten the tunnel length from 212 m to 184 m. [3][4] The final design of XVTS system is completed. The major subjects presented in this report are: (1) Design of the complete system. (2) System analysis results. (3) ES&H issues and plan. (4) Project cost estimates and schedule.« less
  • The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration,more » and the cost estimates.« less
  • The attenuator system for the Linac Coherent Light Source (LCLS) X-ray Transport, Optics and Diagnostics (XTOD) system has been configured and analyzed by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The system layout, performance analyses and selection of the vacuum components are presented in this System Conceptual Review (SCR) report. Also included are the plans for prototype, procurement, mechanical integration, and the cost estimates.
  • The Double-Shell Tank (DST) System is required to transition from its current storage mission to a storage and retrieval mission supporting the River Protection Project Phase 1 privatization, defined in HNF-SD-WM-MAR-008, Tank Waste Remediation System Mission Analysis Report. Requirements for the DST subsystems are being developed using the top-down systems engineering process outlined in HNF-SD-WM-SEMP-002, Tank Waste Remediation System Systems Engineering Management Plan. This top-down process considers existing designs to the extent that these designs impose unavoidable constraints on the Phase 1 mission. Existing engineering-basis documents were screened, and the unavoidable constraints were identified. The constraints identified herein will bemore » added to the DST System specification (HNF-SD-WM-TRD-007, System Specification for the Double-Shell Tank System). While the letter revisions of the DST System specification were constructed with a less rigorous review of the existing engineering-basis documents, the Revision 0 release of the specification must incorporate the results of the review documented herein. The purpose of this document is to describe the screening process and criteria used to determine which constraints are unavoidable and to document the screening results.« less
  • This document contains the system specifications derived to satisfy the system requirements found in the IDC System Requirements Document for the IDC Re-Engineering Phase 2 project. This System Specification Document (SSD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data but does include requirements for the dissemination of radionuclide datamore » and products.« less