Title: Undulator for the LCLS project - changes in the magnet structure design.

Abstract

The design modifications of a new hybrid-type undulator with a fixed gap of 6.8 mm, a period of 30 mm and a length of 3.4 m are presented. The prior pole design included side 'wings, s' which were used for precise positioning, and clamps to fasten the poles to the magnet base. This design has been replaced by a more straightforward assembly, where the pole is attached to the magnet structure base using only two screws. Tests were performed on the vanadium permendur pole material to prove that the threaded holes are easy to fabricate and are able to successfully withstand the torque required to hold the pole in place. A fixture was also developed to ensure the precise location of the poles on the base during assembly. In addition to the pole modifications, the magnet-structure base is now manufactured as one piece as opposed to three, which greatly eases assembly. Finally, a small section of the original prototype had these changes successfully implemented, and the test results are presented.

Authors:
; ; ;  [1]
  1. (APS)
Publication Date:
Research Org.:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
925240
Report Number(s):
ANL/XFD/CP-115105
TRN: US0802385
DOE Contract Number:  
DE-AC02-06CH11357
Resource Type:
Conference
Resource Relation:
Conference: 2005 Particle Accelerator Conference (PAC2005); May 16-20, 2005; Knoxville, TN
Country of Publication:
United States
Language:
ENGLISH
Subject:
43 PARTICLE ACCELERATORS; 36 MATERIALS SCIENCE; ACCELERATORS; DESIGN; MAGNETS; MODIFICATIONS; PERMENDUR; POSITIONING; TORQUE; VANADIUM; WIGGLER MAGNETS

Citation Formats

Trakhtenberg, E., Erdmann, M., Powers, T., and Experimental Facilities Division. Undulator for the LCLS project - changes in the magnet structure design.. United States: N. p., 2005. Web.
Trakhtenberg, E., Erdmann, M., Powers, T., & Experimental Facilities Division. Undulator for the LCLS project - changes in the magnet structure design.. United States.
Trakhtenberg, E., Erdmann, M., Powers, T., and Experimental Facilities Division. Sat . "Undulator for the LCLS project - changes in the magnet structure design.". United States.
@article{osti_925240,
title = {Undulator for the LCLS project - changes in the magnet structure design.},
author = {Trakhtenberg, E. and Erdmann, M. and Powers, T. and Experimental Facilities Division},
abstractNote = {The design modifications of a new hybrid-type undulator with a fixed gap of 6.8 mm, a period of 30 mm and a length of 3.4 m are presented. The prior pole design included side 'wings, s' which were used for precise positioning, and clamps to fasten the poles to the magnet base. This design has been replaced by a more straightforward assembly, where the pole is attached to the magnet structure base using only two screws. Tests were performed on the vanadium permendur pole material to prove that the threaded holes are easy to fabricate and are able to successfully withstand the torque required to hold the pole in place. A fixture was also developed to ensure the precise location of the poles on the base during assembly. In addition to the pole modifications, the magnet-structure base is now manufactured as one piece as opposed to three, which greatly eases assembly. Finally, a small section of the original prototype had these changes successfully implemented, and the test results are presented.},