skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Dose homogeneity in boron neutron capture therapy using an epithermal neutron beam

Journal Article · · Radiation Research
DOI:https://doi.org/10.2307/3579142· OSTI ID:90902
; ;  [1]
  1. Netherlands Cancer Institute, Amsterdam (Netherlands); and others

Simulation models based on the neutron and photon Monte Carlo code MCNP were used to study the therapeutic possibilities of the HB11 epithermal neutron beam at the High Flux Reactor in Petten. Irradiations were simulated in two types of phantoms filled with water or tissue-equivalent material for benchmark treatment planning calculations. In a cuboid phantom the influence of different field sizes on the thermal-neutron-induced dose distribution was investigated. Various shapes of collimators were studied to test their efficacy in optimizing the thermal-neutron distribution over a planning target volume and healthy tissues. Using circular collimators of 8, 12 and 15 cm diameter it was shown that with the 15-cm field a relatively larger volume within 85% of the maximum neutron-induced dose was obtained than with the 8- or 12-cm-diameter field. However, even for this large field the maximum diameter of this volume was 7.5 cm. In an ellipsoid head phantom the neutron-induced dose was calculated assuming the skull to contain 10 ppm {sup 10}B, the brain 5 ppm {sup 10}B and the tumor 30 ppm {sup 10}B. It was found that with a single 15-cm-diameter circular beam a very inhomogeneous dose distribution in a typical target volume was obtained. Applying two equally weighted opposing 15-cm-diameter fields, however, a dose homogeneity within {+-} 10% in this planning target volume was obtained. The dose in the surrounding healthy brain tissue is 30% at maximum of the dose in the center of the target volume. Contrary to the situation for the 8-cm field, combining four fields of 15 cm diameter gave no large improvement of the dose homogeneity over the target volume or a lower maximum dose in the healthy brain. Therapy with BNCT on brain tumors must be performed either with an 8-cm four-field irradiation or with two opposing 15- or 12-cm fields to obtain an optimal dose distribution. 27 refs., 10 figs., 3 tabs.

Sponsoring Organization:
USDOE
OSTI ID:
90902
Journal Information:
Radiation Research, Vol. 142, Issue 3; Other Information: PBD: Jun 1995
Country of Publication:
United States
Language:
English