skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Geant4-A Simulation Toolkit

Abstract

No abstract prepared.

Authors:
;
Publication Date:
Research Org.:
Stanford Linear Accelerator Center (SLAC)
Sponsoring Org.:
USDOE
OSTI Identifier:
903313
Report Number(s):
SLAC-REPRINT-2006-223
Journal ID: ISSN 0003-018X; TANSAO; TRN: US0703220
DOE Contract Number:
AC02-76SF00515
Resource Type:
Journal Article
Resource Relation:
Journal Name: Trans.Amer.Nucl.Soc.95:757,2006; Journal Volume: 95
Country of Publication:
United States
Language:
English
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; 99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE; COMPUTERIZED SIMULATION; NUCLEAR PHYSICS; G CODES; Other,OTHER

Citation Formats

Asai, M., and /SLAC. Geant4-A Simulation Toolkit. United States: N. p., 2007. Web.
Asai, M., & /SLAC. Geant4-A Simulation Toolkit. United States.
Asai, M., and /SLAC. Mon . "Geant4-A Simulation Toolkit". United States. doi:.
@article{osti_903313,
title = {Geant4-A Simulation Toolkit},
author = {Asai, M. and /SLAC},
abstractNote = {No abstract prepared.},
doi = {},
journal = {Trans.Amer.Nucl.Soc.95:757,2006},
number = ,
volume = 95,
place = {United States},
year = {Mon May 07 00:00:00 EDT 2007},
month = {Mon May 07 00:00:00 EDT 2007}
}
  • We report that a revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research andmore » other low energy physics fields.« less
  • Geant4 is a Monte Carlo simulation Toolkit, describing the interactions of particles with matter. Geant4 is widely used in radiation physics research, from High Energy Physics, to medical physics and space science, thanks to its sophisticated physics component, coupled with advanced functionality in geometry description. Geant4 is widely used at the Centre for Medical Radiation Physics (CMRP), at the University of Wollongong, to characterise and optimise novel detector concepts, radiotherapy treatments, and imaging solutions. This lecture consists of an introduction to Monte Carlo method, and to Geant4. Particular attention will be devoted to the Geant4 physics component, and to themore » physics models describing electromagnetic and hadronic physics interactions. The second part of the lecture will be focused on the methodology to adopt to develop a Geant4 simulation application.« less
  • Purpose: Proton therapy exhibits several advantages over photon therapy due to depth-dose distributions from proton interactions within the target material. However, uncertainties associated with protons beam range in the patient limit the advantage of proton therapy applications. To quantify beam range, positron-emitting nuclei (PEN) and prompt gamma (PG) techniques have been developed. These techniques use de-excitation photons to describe the location of the beam in the patient. To develop a detector system for implementing the PG technique for range verification applications in proton therapy, we studied the yields, energy and angular distributions of the secondary particles emitted from a PMMAmore » phantom. Methods: Proton pencil beams of various energies incident onto a PMMA phantom with dimensions of 5 x 5 x 50 cm3 were used for simulation with the Geant4 toolkit using the standard electromagnetic packages as well as the packages based on the binary-cascade nuclear model. The emitted secondary particles are analyzed . Results: For 160 MeV incident protons, the yields of secondary neutrons and photons per 100 incident protons were ~6 and ~15 respectively. Secondary photon energy spectrum showed several energy peaks in the range between 0 and 10 MeV. The energy peaks located between 4 and 6 MeV were attributed to originate from direct proton interactions with 12C (~ 4.4 MeV) and 16O (~ 6 MeV), respectively. Most of the escaping secondary neutrons were found to have energies between 10 and 100 MeV. Isotropic emissions were found for lower energy neutrons (<10 MeV) and photons for all energies, while higher energy neutrons were emitted predominantly in the forward direction. The yields of emitted photons and neutrons increased with the increase of incident proton energies. Conclusions: A detector system is currently being developed incorporating the yields, energy and angular distributions of secondary particles from proton interactions obtained from this study.« less
  • It is proposed to use 14 MeV neutrons tagged by the associated particle neutron time-of-flight technique (APnTOF) to identify the fillers of unexploded ordnances (UXO) by characterizing their carbon, nitrogen and oxygen contents. To facilitate the design and construction of a prototype system, a preliminary simulation model was developed, using the Geant4 toolkit. This work established the toolkit environment for (a) generating tagged neutrons, (b) their transport and interactions within a sample to induce emission and detection of characteristic gamma-rays, and (c) 2D and 3D-image reconstruction of the interrogated object using the neutron and gamma-ray time-of-flight information. Using the modeling,more » this article demonstrates the novelty of the tagged-neutron approach for extracting useful signals with high signal-to-background discrimination of an object-of-interest from that of its environment. Simulations indicated that an UXO filled with the RDX explosive, hexogen (C{sub 3}H{sub 6}O{sub 6}N{sub 6}), can be identified to a depth of 20 cm when buried in soil.« less
  • Theoretical dose distributions for microbeam radiation therapy (MRT) are computed in this paper using the GEANT4 Monte Carlo (MC) simulation toolkit. MRT is an innovative experimental radiotherapy technique carried out using an array of parallel microbeams of synchrotron-wiggler-generated x rays. Although the biological mechanisms underlying the effects of microbeams are still largely unknown, the effectiveness of MRT can be traced back to the natural ability of normal tissues to rapidly repair small damages to the vasculature, and on the lack of a similar healing process in tumoral tissues. Contrary to conventional therapy, in which each beam is at least severalmore » millimeters wide, the narrowness of the microbeams allows a rapid regeneration of the blood vessels along the beams' trajectories. For this reason the calculation of the 'valley' dose is of crucial importance and the correct use of MC codes for such purposes must be understood. GEANT4 offers, in addition to the standard libraries, a specialized package specifically designed to deal with electromagnetic interactions of particles with matter for energies down to 250 eV. This package implements two different approaches for electron and photon transport, one based on evaluated data libraries, the other adopting analytical models. These features are exploited to cross-check theoretical computations for MRT. The lateral and depth dose profiles are studied for the irradiation of a 20 cm diameter, 20 cm long cylindrical phantom, with cylindrical sources of different size and energy. Microbeam arrays are simulated with the aid of superposition algorithms, and the ratios of peak-to-valley doses are computed for typical cases used in preclinical assays. Dose profiles obtained using the GEANT4 evaluated data libraries and analytical models are compared with simulation results previously obtained using the PENELOPE code. The results show that dose profiles computed with GEANT4's analytical model are almost indistinguishable from those obtained with the PENELOPE code, but some noticeable differences appear when the evaluated data libraries are used.« less