FAST COMPENSATION OF GLOBAL LINEAR COUPLING IN RHIC USING AC DIPOLES.
Conference
·
OSTI ID:895875
Global linear coupling has been extensively studied in accelerators and several methods have been developed to compensate the coupling coefficient C using skew quadrupole families scans. However, scanning techniques can become very time consuming especially during the commissioning of an energy ramp. In this paper they illustrate a new technique to measure and compensate, in a single machine cycle, global linear coupling from turn-by-turn BPM data without the need of a skew quadrupole scan. The algorithm is applied to RHIC BPM data using AC dipoles and compared with traditional methods.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- DOE/SC
- DOE Contract Number:
- DE-AC02-98CH10886
- OSTI ID:
- 895875
- Report Number(s):
- BNL-75456-2006-CP; R&D Project: 18026; KB0202011; TRN: US0700547
- Resource Relation:
- Conference: EPAC'06 - 10TH BIENNIAL EUROPEAN PARTICLE ACCELERATOR CONFERENCE; EDINBURGH, UK; 20060626 through 20060630
- Country of Publication:
- United States
- Language:
- English