Title: High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry Analyzers

Journal Article · · Analytical Chemistry, 78(11):3706-3714
DOI:https://doi.org/10.1021/ac052020v· OSTI ID:885457

Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as a powerful tool of broad utility for separation and characterization of gas-phase ions, especially in conjunction with mass spectrometry (MS). In FAIMS, ions are filtered by the dependence of mobility on electric field while carried by gas flow through the analytical gap between two electrodes of either planar (p-) or cylindrical (c-) geometry. Most FAIMS/MS systems employ c-FAIMS because of its ease of coupling to MS, yet the merits of two geometries have not been compared in detail. Here, a priori simulations have revealed that reducing the FAIMS curvature always improves resolution at equal sensitivity. In particular, the resolving power of p-FAIMS exceeds that of c-FAIMS, typically by a factor of 2 - 4 depending on the ion species and carrier gas. We have constructed a new planar FAIMS that incorporates a curtain plate interface for effective operation with an ESI ion source and is joined to MS using an ion funnel interface with a novel slit aperture. The resolution increases up to 4-fold over existing c-FAIMS, even though the analysis is ~3 times faster. This allows separation of species not feasible in previous FAIMS studies, e.g., protonated leucine and isoleucine or new bradykinin isomers. The improvement for protein conformers (of ubiquitin) is less significant, possibly because of multiple unresolved geometries.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
885457
Report Number(s):
PNNL-SA-47897; 400412000; TRN: US200616%%650
Journal Information:
Analytical Chemistry, 78(11):3706-3714, Vol. 78, Issue 11
Country of Publication:
United States
Language:
English

Similar Records

Improving FAIMS Sensitivity using a Planar Geometry with Slit Interfaces
Journal Article · Tue Sep 01 00:00:00 EDT 2009 · Journal of the American Society for Mass Spectrometry, 20(9):1768-1774 · OSTI ID:885457

Distortion of Ion Structures by Field Asymmetric Waveform Ion Mobility Spectrometry
Journal Article · Thu Feb 15 00:00:00 EST 2007 · Analytical Chemistry, 79(4):1523-1528 · OSTI ID:885457

Characterizing the Structures and Folding of Free Proteins Using 2-D Gas-Phase Separations: Observation of Multiple Unfolded Conformers
Journal Article · Mon May 15 00:00:00 EDT 2006 · Analytical Chemistry, 78(10):3304-3315 · OSTI ID:885457