skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Ultra-Fast Pump-Probe Detection Using Plasmas

Abstract

The temporal resolution of pump-flash interactions in the femtosecond-attosecond (fs-as) regime is limited by the characteristic time constants of the excited states in the detector material. If the relaxation time constant is appreciably longer that the time interval between the pump and probe signals the response of the detector material to the probe represents a temporal convolution with the pump and probe responses, setting a lower limit on the resolution to which the interval between the two pulses can be measured. In most of the solid state ultrafast detection schemes that are being considered for the ultrashort pulse x-ray sources under current development at SLAC and elsewhere the characteristic time constants are related to the bound states of the atoms comprising the material or to the relaxation times of phase transitions or charge carrier populations of the lattice, setting a probable lower limit on the attainable resolution on the order of {approx}0.1 ps. In this paper we consider a novel detection principle based on the excitation of specially prepared unbound states in an ionized plasma with high pump and probe fields, and estimate its potential for extending the lower limit of resolution into the attosecond (as) regime.

Authors:
;
Publication Date:
Research Org.:
Stanford Linear Accelerator Center (SLAC)
Sponsoring Org.:
USDOE
OSTI Identifier:
876445
Report Number(s):
SLAC-PUB-11603
/; TRN: US200606%%808
DOE Contract Number:
AC02-76SF00515
Resource Type:
Conference
Resource Relation:
Conference: Presented at the 27th International Free Electron Laser Conference (FEL 2005), Stanford, California, 22-26 August 2005
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ATOMS; BOUND STATE; CHARGE CARRIERS; DETECTION; EXCITATION; EXCITED STATES; FREE ELECTRON LASERS; PLASMA; PROBES; RELAXATION TIME; RESOLUTION; STANFORD LINEAR ACCELERATOR CENTER; X-RAY SOURCES; Accelerators,XFEL

Citation Formats

Tatchyn, R., and /SLAC. Ultra-Fast Pump-Probe Detection Using Plasmas. United States: N. p., 2006. Web.
Tatchyn, R., & /SLAC. Ultra-Fast Pump-Probe Detection Using Plasmas. United States.
Tatchyn, R., and /SLAC. Fri . "Ultra-Fast Pump-Probe Detection Using Plasmas". United States. doi:. https://www.osti.gov/servlets/purl/876445.
@article{osti_876445,
title = {Ultra-Fast Pump-Probe Detection Using Plasmas},
author = {Tatchyn, R. and /SLAC},
abstractNote = {The temporal resolution of pump-flash interactions in the femtosecond-attosecond (fs-as) regime is limited by the characteristic time constants of the excited states in the detector material. If the relaxation time constant is appreciably longer that the time interval between the pump and probe signals the response of the detector material to the probe represents a temporal convolution with the pump and probe responses, setting a lower limit on the resolution to which the interval between the two pulses can be measured. In most of the solid state ultrafast detection schemes that are being considered for the ultrashort pulse x-ray sources under current development at SLAC and elsewhere the characteristic time constants are related to the bound states of the atoms comprising the material or to the relaxation times of phase transitions or charge carrier populations of the lattice, setting a probable lower limit on the attainable resolution on the order of {approx}0.1 ps. In this paper we consider a novel detection principle based on the excitation of specially prepared unbound states in an ionized plasma with high pump and probe fields, and estimate its potential for extending the lower limit of resolution into the attosecond (as) regime.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Feb 17 00:00:00 EST 2006},
month = {Fri Feb 17 00:00:00 EST 2006}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 {mu}m) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneablemore » 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 {mu}m range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.« less
  • We demonstrate a pump-probe approach for the detection of organophosphonate compounds on substrates, in which the pump pulse fragments the parent molecule and the released phosphorous monoxide (PO) fragment is probed using laser-induced fluorescence.
  • Abstract not provided.
  • No abstract prepared.